Senect O2S-20-SC Скачать руководство пользователя страница 6

General Security Notes 

 

 

6

 

 

The operating temperature of the device must be between 
0°C and +40°C. It is not allowed to modify the sensor, to open 
the housing or to insert anything into the housing. 

The  oxygen  sensor  O2S  is  designed  to  be  operated  by 
professional users. However, it can be operated by children 
of  the  age  of  at  least  8  years  and  persons  with  limited 
physical, sensorial or cognitive ability, if they are supervised 
and  trained  in  the  usage  of  the  instrument,  so  that  no 
dangers or threats can result of the operation.  

Please store this manual. We suggest the storage a copy of 
the manual in the vicinity of the device. 

Technical and optical changes of this manual are subject to 
alterations.  

 

Warning:  Before  starting  any  maintenance  work, 
unplug all electrical devices in the water. 

 

 

 

Содержание O2S-20-SC

Страница 1: ...Oxygen Sensor O2S Manual...

Страница 2: ...ECT GmbH Co KG An 44 No 11 76829 Landau Germany Important note Please read this manual carefully and store it so that you can use it later Read the warning and safety notes attentive Further informati...

Страница 3: ...Maintenance and cleaning 12 Cleaning 12 Sensor disinfection 12 Recalibration 13 Oxygen signal 1 Point calibration 15 Short version Oxygen signal 1 Point calibration 17 Oxygen signal 2 Point Calibratio...

Страница 4: ...RNING Warning of possible life threatening and or severe irreversible injuries ATTENTION Warning of possible medium or slight injury ATTENTION Follow the notes to avoid damage of equipment NOTE Furthe...

Страница 5: ...ure that all cables are installed safely so that no obstacles for persons are built and all Mount all cables and electric devices protected against direct environmental impacts like overheating by dir...

Страница 6: ...by children of the age of at least 8 years and persons with limited physical sensorial or cognitive ability if they are supervised and trained in the usage of the instrument so that no dangers or thre...

Страница 7: ...s or 0 to 20 mg O2 l at temperatures between 0 C and 40 C The sensor measures the saturation concentration based on the principle of luminescence quenching with a resolution of 1 a s or 0 1 mg l and t...

Страница 8: ...14 days Unfortunately we cannot accept later information of damage which happened during the transport Installation and start up Choose a place for the electronic interface of the O2S which is clean...

Страница 9: ...ing on a float or completely submerged Fig 1 Mounting possibilities of the sensor Please consider when selecting the mounting location that in surface waters like fish ponds the solar radiation can le...

Страница 10: ...fers protection cages Connect the blue marked plug of the sensor with a sensor input port also blue marked of your control unit The SENECT control units recognize the sensor itself and start automatic...

Страница 11: ...or aquaculture typical environmental conditions after 6 months Getting started Short version 1 Mount the sensor submerged 2 Mount the black electronic interface at a protected location 3 Connect the s...

Страница 12: ...ration of the biofilm and not of the surrounding water Cleaning The sensor should be cleaned regularly by wiping with a soft water dipped paper towel or a cotton swab without cleaning agents Avoid the...

Страница 13: ...itions the sensor must be recalibrated more frequently to guarantee precise measurements Please check regularly the oxygen reading of the sensor when it is placed in humid air Since the florescent mem...

Страница 14: ...a s 0 a s 100 a s Factory settings Temperature Calibration Point 1 Calibration Point 2 Information Info to SENECT Alarm Threshold Lower Threshold O2 Upper Threshold O2 Hysteresis O2 Lower Threshold C...

Страница 15: ...ted air and ensure that there are no water drops on the membrane Select in the menu Sensors the oxygen sensor O2S and choose Sensor calibration O2 a s Select 100 a s Calibration Point 2 to take up the...

Страница 16: ...naccuracies can be created by The air is injected with a pressure exceeding atmospheric pressure Therefore the partial pressure of O2 can also be slightly increased The exact timing when 100 saturatio...

Страница 17: ...n air Additionally perform the same procedure when the sensor is submerged in oxygen free water You can create an oxygen free solution by adding 1 tea spoon of sodium sulphite in 100 ml water concentr...

Страница 18: ...sensor in a water bath with the lower temperature calibration point 1 and wait until the sensor has the same temperature as the water Select in the menu Sensors O2S Sensor Calibration Temperature Cal...

Страница 19: ...libration point 2 e g 0 C The SENECT control units measure the atmospheric pressure and use this value for an automatic pressure compensation Sensor Error In case the sensor or the sensing membrane is...

Страница 20: ...utomatic salinity correction based on conductivity measurements for the oxygen measurement can be made Sensors O2S Salinity correction Mode From sensor cor In case there is no conductivity sensor conn...

Страница 21: ...5 8400 25 35400 6 9900 26 36700 7 11300 27 37900 8 12800 28 39200 9 14200 29 40400 10 15600 30 41700 11 17000 31 43000 12 18900 32 44200 13 19700 33 45400 14 21100 34 46700 15 22400 35 47900 16 23800...

Страница 22: ...mm Weight probe ca 100 g Cable length total 10 m Voltage 24 V DC Power consumption 1 W Temperature range 0 to 40 C Max pressure 3 bar Measurement range 0 200 0 20 mg O2 l 1 Precision oxygen 1 FS Preci...

Страница 23: ...tion about the correct disposal 23 Dimensions in mm not to scale stainless steel 1 4435 exchangeable sensor cap L 5 m 5 172 40 d 30 L 5 m 5 14 Interface silicone housing 81 4 12 4 29 Fig 3 Sensor dime...

Страница 24: ...roduct back to the producer The SENECT GmbH Co KG is member of the Stiftung Elektro Altger te Register and the products are registered WEEE Reg Nr DE37193510 Guarantee Please check at delivery of your...

Отзывы: