5 INSTALLATION STANDARDS 

The module has been designed for vertical installation on an IEC EN 60715 DIN rail. For optimal 
operation and long working life, adequate ventilation must be provided. Avoid positioning cable ducts or 
other objects so that they obstruct the ventilation slots. Avoid mounting modules over equipment 
generating heat. Installation in the bottom part of the distribution board

 

is recommended. 

OMEGA IEC EN 60715 guide installation and removal. 

Insertion into the IEC EN 60715 guide: 
1) Move the two hooks on the back of the module
outwards as illustrated in fig. 1b.
2) Rest the module on the IEC EN 60715 DIN
guide.
3) To secure the module to the IEC EN 60715
DIN rail, tighten the two hooks on the side of the
IDC10 rear connector as shown in fig. 1a.

Removal from the IEC EN 60715 guide: 
As shown in figure 1b:  
1) Move outwards the two hooks on the side
of the module, with the help of a screwdriver.
2) Extract the module from the guide.

Use of Z-PC-DINAL2-17.5 accessory 

If Z-PC-DINAL2-17.5 accessory is used, the 
power supply and communication signals may 
be provided by the terminals block into the DIN 
rail support. The figure shows the meaning of 
the terminal blocks and the position of the DIP-
switch in the Seneca IEC EN 60715 DIN rail 
accessory. 
GNDSHLD: Shield to protect the connection 
cables against interference (recommended). 

IDC10 rear connector 

The IDC10 connector located on the rear of the 
module will be inserted on a free slot of Z-PC-DIN 
accessory. In the figure you can see the meaning 
of the IDC10 connector pins if you want to provide 
signals through them. The IDC10 connector 
provides the COM 2 RS485 port. 

MI00367

-3

-E 

Содержание Z-TWS11

Страница 1: ... PANEL MODULE LAYOUT 11 DECOMMISSIONING AND DISPOSAL Factory Seneca srl Headquarters Via Austria 26 35127 Z I Padova IT Phone 39 049 8705355 8705355 Fax 39 049 8706287 Site www seneca it Mail Technical support support seneca it Product Informations sales seneca it This document is property of SENECA srl Duplication and reproduction are forbidden if not authorized The content of the present documen...

Страница 2: ...INSTRUCTIONS It is forbidden block the ventilation slots with any object It is forbidden to install the module near heat sources Warning Do not turn off the Z TWS 11 module while writing the micro SD card so as not to corrupt the file system For data logging applications on micro SD card you must use an external UPS 3 GENERAL SPECIFICATIONS Multifunction and multi protocol control unit Module conf...

Страница 3: ...32GByte Power supply Voltage 11 40 VC 19 28 VA 50 60 Hz Power consumption Typical 1 5 W 24V max 2 W Environmental conditions Temperature From 10 to 50 C Humidity 30 90 not condensing Storage temperature From 20 to 85 C Protection degree IP20 Overall dimensions Case Dimensions Weight L 100 mm H 111 mm W 17 5 mm 104 gr Case PA6 black Insulations Standards The instrument complies with the following s...

Страница 4: ... of the IDC10 rear connector as shown in fig 1a Removal from the IEC EN 60715 guide As shown in figure 1b 1 Move outwards the two hooks on the side of the module with the help of a screwdriver 2 Extract the module from the guide Use of Z PC DINAL2 17 5 accessory If Z PC DINAL2 17 5 accessory is used the power supply and communication signals may be provided by the terminals block into the DIN rail...

Страница 5: ...gurable analog inputs For the configuration software you can read the user manual Connection of COM4 RS485 serial port SW2 OFF Z TWS11 has a serial port configurable through the SW2 Switch If the switch SW2 is set to OFF position then the RS485 serial port COM4 is available to terminals 10 11 12 The picture shows how to make the connection Connection of COM4 RS232 serial port SW2 ON Z TWS11 has a ...

Страница 6: ...W1 KEY Turn off the Z TWS11 module and set to ON all eight DIP switches SW1 Turn on the Z TWS11 module and then wait 10 seconds Turn off the Z TWS11 module and set to OFF all eight DIP switches SW1 ON 1 OFF 0 SW2 Switch setting RS232 or RS485 configuration on terminals 10 11 12 serial port COM 4 SW2 KEY RS232 ON 1 RS485 OFF 0 8 LED SIGNALING ON THE FRONTAL PANEL LED STATUS LEDs meaning Tx1 Red Bli...

Страница 7: ... the product is suitably discarded will avoid potential negative impacts on the environment and human health that could be caused by non compliant product disposal Material recycling will contribute to the preservation of natural resources To receive further information please contact your local waste disposal service center or product dealer For the Z TWS11 configuration use the EASY SETUP softwa...

Отзывы: