MI002191-I-E
MI002191-I-E
ENGLISH 6/8
7.0 CONFIGURATION AND SETTINGS
7.1 Frontal Dip-switch
7.2 Software configuration
The first time the module is not configured, therefore in the following steps are present
some simple instruction to download the software configuration.
Turn off the module.
Open the plastic side of the box.
Enable the DIP-switch for «BOOT» mode
Turn ON the module, the
led blink quickly.
Now connect the DB9 cable (Z107E to PC)(PM002490).
Open the configuration software: COMPOSITOR(*).
Set the configuration parameters for yours application.
Download the configuration to the module by
When the configuration is installed, TURN OFF the module.
Disable the
.
TAKE OFF the DB9 cable.
Close the plastic side of the box.
Connect the RJ45
Turn on the module.
Open configuration software: SERIALTOETHERNETCONNECTOR(SEC)(*)
Configure the Virtual/RemoteCOM for yours application.
End.
(*) For more information about a configuration software consult the seneca’s configuration
CD
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
·
yellow
DIP-switch for «BOOT»mode
RS232
Z107E
1
2
DIP-Switch
Position
Description
OFF= Restores the normal operation
mode of the Z107E
ON= Enable the «BOOT» mode that
let the software configuration
ON= Enable the terminetor of the
RS485 / R 232
S
communication.
OFF= Disable the terminetor of the
RS485 / R 232 communication.
S
DESCRIPTION
Rx
Tx
Gnd
Rts
Cts
PIN DESCRIPTION
2
Tx
3
Rx
5
Gnd
7
Cts
8
Rts
PIN
2
3
5
7
8
From PC
To Z107E