background image

MODULE LAYOUT

Weight:

 170 g; 

Enclosure:

 Self-extinguishing PC/ABS material, black.

2/8

PRELIMINARY WARNINGS

The word 

WARNING

 preceded by the symbol   indicates conditions or actions that put the user's safety at 

risk. The word 

ATTENTION

 preceded by the symbol 

 indicates conditions or actions that might damage the 

instrument or the connected equipment.

The warranty shall become null and void in the event of improper use or tampering with the module or devices 

supplied by the manufacturer as necessary for its correct operation, and if the instructions contained in this 

manual are not followed.



96 mm

98 mm

48 mm

WARNING

: The full content of this manual must be read before any operation.

The module must only be used by qualified electricians.

Specific documentation is available at www.seneca.it/prodotti/s311d

Electrical and electronic waste disposal (applicable in the European Union and other countries with recycling).

The symbol on the product or its packaging shows the product must be surrendered to a collection centre 

authorized to recycle electrical and electronic waste.

The module must be repaired and damaged parts replaced by the Manufacturer.

The product is sensitive to electrostatic discharges. Take appropriate measures during any operation.

BUTTON POSITION

4-6-8-11-DIGIT DISPLAY

A1: Alarm 1 LED

A2: Alarm 2 LED

OK/MENU KEY

UP KEY

DOWN KEY

Содержание S311D L Series

Страница 1: ...git display advanced digital totalizers indicators SENECA s r l Via Austria 26 35127 PADOVA ITALY Tel 39 049 8705355 8705359 Fax 39 049 8706287 For manuals in other languages and the configuration sof...

Страница 2: ...are not followed 96 mm 98 mm 48 mm WARNING The full content of this manual must be read before any operation The module must only be used by qualified electricians Specific documentation is available...

Страница 3: ...pacity 8 A 250 Vac available only on optional board AUX DIGITAL INPUT Optoinsulated Vmin 10 V Vmax 30 V available only on optional board OPERATION DESCRIPTION The measurement of the digital input freq...

Страница 4: ...nit at each rising edge of the digital input Decreasing it is decreased by one unit at each rising edge of the digital input Once the maximum or minimum limit is reached counting restarts from zero It...

Страница 5: ...l power supply for the sensors equal to 17 Vdc is available at terminals 7 and 10 03 04 05 06 VOLTAGE V 03 04 05 06 APPLIED CURRENT A Active output already powered to be connected to passive inputs 03...

Страница 6: ...imum value 0 Max value depending on the display 4 11 4 7 digits 9999 without decimal point 6 8 digits 10000 without decimal point 1000 Hz dpIn Position of decimal point in HI F 0 no decimal point e g...

Страница 7: ...on the minimum held threshold does not automatically reset 4 Alarm on the maximum held threshold does not automatically reset 5 Alarm on the totalizer threshold value does not automatically reset 0 N...

Страница 8: ...N digits display 1 For 11 digit models 4 7 max number of decimal places equal to 6 0 No decimal point e H I t Confirming with OK MENU you save all parameters on a flash card and after a few moments re...

Отзывы: