background image

Sencore understands that each customer is unique - a solution designed for one customer does not 

necessarily suit another customer. Hence, head-ends are tailor made according to customers’ specific 

needs - down to the available rack space. We start with an input, output, and a power module. Then, 

depending on your requirements, any number of combinations is possible by installing the module that 

corresponds to your need. In short, our promise is not a generic one size fits all solution, but a dynamic, 

tailor-made solution allowing for future modification.

Design Philosophy

The unit is designed with reliability and flexibility in mind. It consists of a chassis in which a number of 

hot-swappable cards can be installed. The chassis can be configured to host interface and processing 

cards according to the customer’s requirements. Two different chassis variations are available - a 1RU 

chassis and a 2RU chassis. The product description DMG 4200 represents the 2RU chassis, while the 

product description DMG 4100 represents the 1RU chassis. All chassis variations use the same software 

platform, as well as a HW plugin cards (Except the controller cards).

Unit Architecture

•  Consists of 14 slots(1,2, ... 14).  

•  Slot 1 and 2 in the front, holds mandatory 

controller card, which also includes line 

card functionality. 

•  Slot 3->14, in the back, are optional slots for 

line cards.

The 2RU Chassis - DMG 4200

The 1RU Chassis - DMG 4100

•  Consists of 10 slots (1, 2, … 10).  

•  Slot 1 and 2 in the front, holds 

mandatory controller cards, which also 

includes line card functionality. 

•  Slot 3->18, in the back, are optional 

slots for line cards. These line cards are 

interchangeable between DMG 4100 and 

DMG 4200.

In the chassis, the required controller card provides all the communication between all modules 

allowing 1 to 1 communication between another. With dual controller cards fitted the internal network 

paths are duplicated allowing seamless switch behavior internally.
Access to the unit is provided via the control port of the controller card. The controller card also stores 

the configurations of all the cards.

Chassis Communication

Control Port

Connecting to the device

•  Connect the control port on 

the switch/controller card to 

a PC using an Ethernet cable.

•  Set the IP address of the PC’s 

Ethernet to a fixed address 

in the same segment, e.g 

192.168.1.99

•  Use default login user admin, 

without a password.

•  Type the default IP 

address of the unit: 

https://192.168.1.100 in the 

web browser to display the 

user interface.

If the IP setting has been lost, a 

DIP switch can be used to restore 

factory defaults. Refer to the User 

Manual for more information.

Desktop

The desktop is the main application launcher and system status window. The upper part shows the hardware 

configuration and key status regarding received and transmitted bitrate of the cards.

The center part is the application launcher section. As applications are launched they will appear along the 

lower edge of the desktop for easy access later. In case of many application the search window can be used to 

search for applications.

To revert to the desktop from an application press the icon in the lower left corner.

In the right corner the circles appear when there are active alarm, click the circles to see which ones. The 

alarm history is accessible via the bell symbol, and the person symbol provides info about the current user. 

Отзывы: