background image

- 7 -

 

03/2021

 Copyright © 2020, Fast ČR, a.s.

EN

Humidifier

User's manual

 ■

Prior to using this appliance, please read the user‘s manual thoroughly, even in cases, 

when one has already familiarised themselves with previous use of similar types of 

appliances. Only use the appliance in the manner described in this user’s manual. 

Keep this user‘s manual in a safe place where it can be easily retrieved for future use. 

 ■

We recommend saving the original cardboard box, packaging material, purchase 

receipt and responsibility statement of the vendor or warranty card for at least the 

duration of the legal liability for unsatisfactory performance or quality. In the event 

of transportation, we recommend that you pack the appliance in the original box 

from the manufacturer.

DESCRIPTION OF THE APPLIANCE

A1 

Steam outlet

A2 

Pillow for applying drops of 

aromatic oil

A3 

Water tank

A4 

Filling opening cap on the water 

tank

A5 

Button for On / Off / Operating 

mode selection / Low water level in 

tank indicator

A6 

Timer button

A7 

Anti-slip feet

A8 

Air outlet

A9 

Ultrasound disc

A10 

Water tank illumination

A11 

Base unit

A12 

Float switch

A13 

Power adapter

A14 

Cleaning brush (not shown)

BEFORE FIRST USE

 ■

Before first use, take the appliance and its accessories out of the packaging material 

and remove all promotional labels and stickers. Check that neither the appliance nor 

any of its parts is damaged.

Filling the water tank

1.  Check that the power adapter 

A13

 is disconnected.

2.  Carefully take the water tank 

A3 

off the base unit 

A11

 – see figure 

B1

.

3.  Turn the water tank 

A3

 upside down and screw out the cap 

A4

 – see figure 

B2

.

5.  Pour clean cold water into the water tank 

A3

 – see figure 

B3

.

   Screw on the cap 

A4

 – see figure 

B4

. Check that it is tightened firmly to prevent 

water from leaking. Turn the water tank over 

A3

 so that the cap 

A4

 is pointing 

downwards. If no water is leaking from the water tank 

A3

, then the cap 

A4

 is 

properly tightened.

6.  Put it back on the base 

A11

.

Connecting the power adapter

1.  Insert the connector of the power adapter 

A13

 into the socket located at the rear of 

the base unit 

A11

.

2. Then insert the power adapter plug into a properly grounded power socket. The 

humidifier is now ready for use.

Turning the humidifier on / off and selecting the operating mode

1. Position the humidifier on a  dry, even and water-resistant surface approx. 15 cm 

away from walls and other objects. Ensure that there is sufficient free space around 

the appliance. Do not place the humidifier on carpets, towels, blankets or other 

absorptive materials.

2.  Press button 

A5

 to start the humidifier. The humidifier will automatically start at low 

speed.

3. Repeatedly press button 

A5

 to select one of the following operating modes.

Operating mode

Number of times button 

A5 is pressed

Setting

Mode 1

Once

Low speed

Mode 2

Twice

High speed

Mode 3

Three times

Humidifier is turned off

Turning on / off the water tank illumination

 ■

The water tank illumination can only be turned on / off when the humidifier is 

turned off.

 

Turn on illumination: 

hold down button 

A5

 for approx. 2 seconds.

 

Turn off illumination: 

hold down button 

A5

 for approx. 2 seconds.

Note:

The illumination will remain lit also when the water in the water tank 

A3

 runs out. Turning off the humidifier will not turn off the illumination 

function.

Timer

 ■

The timer function enables a time to be set for which the humidifier will run. To set 

the timer, use button 

A6

. Repeatedly press button 

A6

 to change the duration of 

the timer in the following order: 1 hour – 3 hours – 6 hours. Each time the button is 

pressed, the respective indicator light will be lit and the countdown will start.

 ■

If the timer is set to 3 or 6 hours, the remaining time indicator lights will gradually 

turn off and on.

Low water level indicator

 ■

When the water level falls below the set level, the backlight of button 

A5

 will change 

from blue to red and the humidifier will turn off automatically.

 ■

Add water if necessary. Prior to adding water, check that the humidifier is turned 

off and that the power adapter 

A13

 is disconnected from the power socket. Then 

you may continue according to the instructions in section „

Filling the water tank

“.

Warning:

Never remove the water tank 

A3

 from the base unit 

A11

 while 

the humidifier is running. This would automatically turn off the 

humidifier and creates a  risk of its irreversible damage, risk of 

a dangerous situation arising and risk of injury.

Setting the direction of outflowing steam

 ■

The direction of the outflowing steam can be adjusted within an angle of 360 ° by 

turning the steam outlet nozzle 

A1

.

Aromatic oil

 ■

This humidifier has been designed to enable the use of aromatic oil in it. Next to the 

steam outlet there is a special pillow 

A2

, on to which drops of aromatic oil can be 

applied. 

ALWAYS USE ONLY 3 DROPS OF AROMATIC OIL

.

Warning:

Under no condition pour aromatic oil into the water tank 

A3

 or 

into the base unit 

A11

. This risks damaging the inner parts of the 

humidifier.

CLEANING AND MAINTENANCE

 ■

Disconnect the adapter power plug from the power socket and allow the appliance 

to cool down before cleaning it.

 ■

Adhere to the following instructions relating to the cleaning and maintenance of the 

humidifier. Otherwise its performance may be negatively affected and undesirable 

microorganisms may multiply inside.

Warning:

To prevent the risk of injury by electrical shock, do not submerge 

the appliance, the adapter or its power cord in water or any 

another liquid.

Clean after every use

1. Turn off the humidifier and disconnect the power adapter 

A13

 from the power 

socket.

2. Take the water tank 

A3

 off the base unit 

A11

.

3. Screw off the cap 

A4

 and pour any remaining water out into the sink or down the 

drain.

4.  Rinse out the water tank using clean water and remove any dirt or deposits out of it.

5. Wipe it with a dry wiping cloth.

6. To clean the base unit 

A11

, use a clean soft wiping cloth lightly dampened in warm 

water. Wipe dry using a clean wiping cloth.

Note:

For cleaning, do not use cleaning products with an abrasive effect, 

solvents, etc. that could damage the appliance. No part of this appliance 

is intended for washing in a dishwasher.

Warning:

Do not leave water inside the water tank 

A3

 for an extended 

period of time.

Removing limescale deposits

 ■

Depending on the hardness of the water that is used and the frequency of use, 

we recommend regularly removing water scale deposits, at least once per week. 

Limescale deposits can negatively affect the operation of the humidifier and its 

lifetime.

 ■

In the event that your water is too hard, we recommend using distilled water.

1. Turn off the humidifier and disconnect the power adapter 

A13

 from the power 

socket.

2. Take the water tank 

A3

 off the base unit 

A11

.

3. Screw off the cap 

A4

 and pour any remaining water out into the sink or down the 

drain.

4. Fill the water tank 

A3

 with one cup of white vinegar (approx. 200 ml) and allow 

it to act for 15 minutes. Using a cleaning brush with soft bristles, you can remove 

limescale deposits that have accumulated inside the water tank 

A3

.

5. Pour out the contents of the water tank 

A3

 into a sink or down the drain and rinse 

out the water tank 

A3

 using clean cold water.

6. Wipe it with a dry wiping cloth.

Отзывы: