When the load is a resistive load such as incandescent, heater or common power tools, using
electrical appliances can refer to rated power. If the load is inductive and resistive mixed loads
such as fluorescent lamps, mercury lamp, transformers, fans, small blowers or inductors,using
electrical appliances can only refer to 60% rated power.
NOTICE: WHEN GENERATOR REACH OPERATING SPEED THEN CAN ADD LOAD .
The following table list shows some household electrical appliances’ power for reference.
Reference table list of electrical appliances
equipment running power(w)
equipment running power(w)
air condition
(
12
,
000
)
170 0(a) lamp bulb 100
charger
(
20 A mp
)
500 microwave oven 700
chain saw 1200 milk cooler 1100(a)
circular saw
(
φ
15 mm
)
900 oil burner 300
coffee pot 1000 Oven 4500
perm machine 700 paint sprayer(1/3HP ) 600(a)
dish-washing machine 1200 paint sprayer 150
flat edge trimmer 500 Radio 200
electric staple gun 1200
Continuous loading
electric stove 1500
refrigerator 600(b)
electric stuffy pot 1250 attemperator 200
reefer 800(b)
immersible pump(1-1/2HP) 2800(a)
Hair Dryer 1200
immersible pump(1HP) 2000(a)
electric hand drill
(
φ
25mm
)
1100 immersible pump(1/2HP) 1500(a)
electric hand drill
(
φ
12mm
)
875 trash pump(1/2HP) 600(a)
electric hand drill
(
φ
10mm
)
500 bench saw 2000(a)
electric hand drill
(
φ
6mm
)
250 television(10”) 500
flat edge trimmer 450 bread maker 1000
home computer 150 dust catcher 250
impact wrench 500 video player 70
household water pump 800(a) water heater 3000
hay mower 1200
(a) Cold to start the motor need 5-7 times rated current.
(b) Because the temperature of the compressor head requirements 15 minutes after restarting
6.2 START ELECTROMOTOR
When start electromotor need large current, some electromotor especially phase motor with low
power is hard to start and needs 5-7 times running current. Capacitor start motor needs 2-4 times
running current. Permanent magnet motor need 1.5-2.5 times running current.
When overloaded, the generator will not run basis on the power characteristic curve, the rotate
speed of diesel engine doesn’t increase, which couldn’t output enough power to drive
electromotor to reach the working speed. The generator could make a response on a large initial
starting current. However, a sharp decline in engine speed, may cause generator stop. If allowed
to run with a very low speed, the motor windings will be ablated in a very short time, in this low
speed operation it could lead to the stator and motor windings burn out soon. Because of starting
a large current just a moment, When the generator speed quickly rises to the operating speed,
11