background image

devices. A building can withstand up to 100,000 volts, but electrical equipment may 
be damaged by just a few volts.   

Direct earth grounding of the antenna and the Lightning Protector is necessary to 

protect the installation from lightning and the build-up of static electricity. 

The ground terminal is located on the lightning protector that attached with this 

unit. Connect one end of the grounding cable to the Ground terminal and the other end 
to a good ground connection. 
 
 

Mounting Instruction 

This power amplifier can be mast mounted using the stainless steel U-bolts as shown 
in Figure 5 and Figure 6. Refer to the sketch for proper positioning. Carefully tighten 
the bolts using the included nuts. Take care not to over-tighten the bolts or cause 
damage to the RF connectors on the amplifier. Because the amplifier is a sealed unit, 
these connectors can not easily be repaired. 
This unit can also be mounted to a flat surface using any of the mounting holes on the 
unit’s mounting flanges. 