background image

IP address configuration 

1)

 

After ensuring the EnGenius device is powered on and plugged in, ensure that your computer is 
on. 

2)

 

For the next steps, refer to your Operating System User Manual. 

3)

 

Once your computer is on, ensure that your TCP/IP is set to 

On

 or 

Enabled

. (In the control panel, 

double click Network Connections and then double click on the connection of your Network 
Interface Card (NIC). Select 

Internet Protocol (TCP/IP)

 and then click on the 

Properties

 button.) 

4)

 

If your PC is already on a computer network, ensure that you have set it to a Static IP Address on 
the interface (or Ethernet card that will use the CAP7250AG/CAP7252AG/CAP7253AG) as 

192.168.1.21 

and the Subnet Mask address as 

255.255.255.0

. (Select 

Use the following IP 

Address

 radio button). Once the computer has been prepared, proceed to setting up the 

CAP7250AG/CAP7252AG/CAP7253AG. 
 

CAP7250AG/CAP7252AG/CAP7253AG Setup 

1)

 

To configure CAP7250AG/CAP7252AG/CAP7253AG, open a web browser (

example:

 Microsoft 

Internet Explorer, Mozilla Firefox, Google Chrome, etc.). 

2)

 

In the address bar of the web browser, enter 

192.168.1.2 

(the default IP address of the 

CAP7250AG/CAP7252AG/CAP7253AG)

 

and hit enter. 

 

3)

 

A login screen will appear. By default, the 
username of the 
CAP7250AG/CAP7252AG/CAP7253AG is 

admin

 and the password is 

admin

. Enter the 

current username and password of the 
CAP7250AG/CAP7252AG/CAP7253AG and 
then click 

Login

. Refer to the 

CAP7250AG/CAP7252AG/CAP7253AG user 
manual on how to change the username and 
password. 

4)

 

After clicking 

Login

 with the correct username 

and password, the 
CAP7250AG/CAP7252AG/CAP7253AG Main Menu will appear. If you are successful, proceed to 
setting up the wireless connection. 

 

 

 

 

 