6. The introduction of the parameter setting

6.1 Sensitivity level setting
When the display shows some error codes during the counting, the user can adjust the according sensitivity level
to make the counting more smoothly.
In the normal state, this machine can enter into the sensitivity level setting by pressing the

UV

and

MG

at the

same time, and press

ADD

or

BATCH

to check each page, then press

+

or

-

to adjust the sensitivity level, then

press the

RESET

to save and exit, the details showed as below:

6.1.1 Voice Switch(optional function):

0

is VOICE off,

1

is VOICE on

the default is

0

.

6.1.2 Fake Enable: fake note counted or not counted.

0

is fake note not counted,

1

is fake note counted; the

default is

0

.

6.1.3 Pcs Compare: showing the previous counting number and the current counting number at the same time.

0

is off,

1

is on; the default is

1

.

6.1.4 External port Sel: external display port selection.

0

is computer communication,

1

is the 4 digit LED

side d LCD external display; the default is

1

.

6.1.5 Slant: slant adjustment.

0

is no adjustment,

1

is medium adjustment,

2

is the senior adjustment;

the default is

1

.

6.1.6 Standby Time: the time of the LCD background automatically off, the default is 3 minutes.

6.1.7 Break Time: the time to stop counting. The range is 10-100ms; the default is 33ms.

6.1.8 Start Val: start sensor sensitivity value, ranging from 0 to 9(

0

is the lowest,

9

is the highest); the

default is

4

.

6.1.9 Reset Val: reset sensor sensitivity value, ranging from 0 to 9(

0

is the lowest,

9

is the highest); the

default is

4

.

6.1.10 Thcount Val: the threshold value of counting tube, ranging from 0-200; the default is 200.

6.1.11 Hole Time: the hole repairing time for the single counting tube.

6.1.12 Lcount Light: left counting tube emitting light value, ranging from 0-99; the default is

80

.

6.1.13 Rcount Light: right counting tube emitting light value, ranging from 0-99; the default is

80

.

6.1.14 UV Light: UV emitting light value, ranging from 0 to 99; the default is

60

.

6.1.15 Double Val: double note sensitivity value, ranging from 0 to 10 (

0

is off,

10

is the highest); the default

is

0

.

6.1.16 Chain Val: chain note sensitivity value, ranging from 0 to 5(

0

is off,

5

is the highest);the default is

3

.

6.1.4 Ext Port Sel: external display port selection.

0

is computer communication,

1

is the 4 digit LED side

Содержание ST-2620

Страница 1: ...BILL COUNTER OPERATION MANUAL BILL COUNTER OPERATION MANUAL...

Страница 2: ...solutions 4 The instruction of the main parts 5 The introduction of the display and keys 6 The introduction of the parameter setting 7 Restore to the factory setting 8 Feeding clearance adjustment 9 P...

Страница 3: ...or Fault Problem with the counting sensor Clean or replace the counting sensor Problem with the relative circuit of the counting sensor in the main board Replace the main board or replace the left rig...

Страница 4: ...ous note detected by MG detection Remove the suspicious note from the stacker press RESET to continue MG sensitivity level is too high Decrease the MG sensitivity level DBL Double note detected by the...

Страница 5: ...ing platform 6 reset sensor 1 hopper fixing screw External display optional 2 power socket 3 power switch 4 USB upgrade port 5 external display port 5 The introduction of the display and keys 5 1 The...

Страница 6: ...10 off 2 In the sensitivity level setting press this key to go to the next page 1 Press this key can clear all the fault message then keeping counting 2 In the sensitivity level setting press this key...

Страница 7: ...s medium adjustment 2 is the senior adjustment the default is 1 6 1 6Standby Time the time of the LCD background automatically off the default is 3 minutes 6 1 7Break Time the time to stop counting Th...