Donning the Semmco Marine 15 EEBD
1. Open the yellow upper latch
lever to remove the lid of the
case. Discard the lid.
2. Remove the Marine 15 EEBD
from the case – pull on the base
of the breathing hose.
N.B. This action automatically activates
the chlorate candle and oxygen fills the
breathing bag.
3. Take a breath and place the neck
straps over the head, adjusting
as required.
4. Insert the yellow mouthpiece,
exhale into the mouthpiece and
breathe normally.
5. Apply the nose clip.
6. If required, pull the faceshield
over the head. Use the pull cords
to snuggly fit the faceshield
around the neck.
N.B. If moisture collects inside the
faceshield and distorts the vision, press
it against the face to clear.
7. Safely escape.
After use
1. Once in a safe area, remove the Marine 15 EEBD.
2. The Semmco Marine 15 EEBD can be returned to
Semmco LPS Ltd for disposal.
Regulations and Approvals
Marine 15 EEBD has been designed and tested in accordance
with the following regulations:
• EN13794 and ISO 23269-1 – to demonstrate compliance
with the essential safety requirements with PPE Regulation
(EU) 2016/425
• SOLAS (International Convention For The Safety of
Life at Sea) – Emergency Escape Breathing Devices
• Marine Equipment Directive 2014/90/EU
Содержание 15 EEBD