8
TROUBLESHOOTING
Danger!
Disconnect from the mains before starting any service work or before removing the cover.
Malfunction:
Standby (5) is not lighting up
Cause:
The door is open
Main switch is OFF
The emergency button is pressed
Key switch is not plugged in
On-site fuse
Machine is overloaded the motor protection switch is re-activated after 10 minutes
Malfunction:
Motor makes a buzzing noise and the machine shows no performance
Cause:
One phase is missing
Remedy:
Check if all three phases are supplied with electric power (voltage) by an electrician
Malfunction:
Machine door is difficult to open
Cause:
Guiding bar of the lower cutting head cover is dirty
Remedy:
Clean and grease the guiding bar
Malfunction:
Machine switches off during normal operation
Cause:
Bag full control light will light – Shred bag is full
Remedy:
Change waste bag
Or
Cause:
Yellow pilot light (7) lights up, temperature of the motor is too high
Remedy:
Wait approximately 10 to 20 until machine cools down
For NATIONWIDE SERVICE Call 1(800)225-9293