Troubleshooting
Hinweise für die Fehlersuche
8. Troubleshooting
Problem
Cause
Solution
Drive does not work
Electric connection defective
Check the connection
Thermal protection switch has
triggered
Wait for 5 to 20 minutes
Drive does not perform a short drive
at initial commissioning
Electric connection defective
Check the connection
End positions are already set
Reset drive to state at delivery
UP and DOWN directions are
switched
End positions set incorrectly
Reset end positions
Drive has stopped auto matically
when moving DOWN
Blockage/obstacle recognition has
triggered
Remove obstacle, check curtain run
Drive has stopped auto matically
when moving UP
Overload recognition has triggered
Remove obstacle, check curtain
path, possibly select stronger drive