EN
39
Comfort switching off
5. Comfort switching off
The relief function at the upper end limit is subsequently disengageable: When comfort
switching off is set, the drive will stop automatically at a point shortly before the upper end
limit. Every 30th move is a reference move against the upper end limit plus relief.
Therefore the noise development when switching off above will be reduced.
A requirement for the setting of the comfort switching off: both end limit positions must be
set, move against the upper end limit plus relief.
Setting with
switch
Setting with
setting switch
Drive
E
Move the drive upwards until it stops automat-
ically at the upper end limit.
1 s
1 s
E
Press the UP button for 1 second.
approx. 3 s
E
approx. 3 s
Press the UP button for approximately 3 sec-
onds until the drive executes a short confirma-
tion move.
When executing this procedure once again it
will lead to the deactivation of the comfort
switching off.
The comfort switching off can also be executed via radio with a commeo hand-held transmit-
ter/wall send. This process is described in chapter 6.2.7. CONFIGURATION mode.