50
Technical data
6. Technical data
Series
Torque
Nm
Rotation speed
Rpm
Power Input
A
Output
1/6
6
15
0.5
115
1/10
10
15
0.5
115
2/6
6
28
0.45
105
2/7
7
17
0.41
95
2/9
9
28
0.66
152
2/10
10
17
0.55
124
2/12
12
28
0.75
172
2/15
15
17
0.66
152
2/18
18
28
1.95
220
2/20
20
17
0.75
172
2/30
30
17
0.95
220
2/40
40
17
1.5
345
2/50
50
12
1.5
345
3/50
50
17
1.4
315
3/60
60
12
1.1
315
3/70
70
17
1.9
435
3/80
80
12
1.4
322
3/120
120
11
1.9
435
Installation location:
After installing the drive, mark the drive type in the technical data table and make a note of
the installation location.
Series 2 motors have a plug in connection cable. Series 1 and series 3 motors have a 2.5 m
mains cable as standard which is permanently installed and cannot be replaced.
The relevant cable lengths and qualities for series 1, series 2 and series 3 can be selec ted in
the catalogue.
Connection cables must be ordered separately.
Information about connections using special connectors must be requested.
Information for all motor types:
Nominal voltage: 230 V AC/50 Hz
Standby consumption: 0.5 W
Safety class: IP 44
Operating time: 4 min.
Radio frequency: 868.1 MHz
Max. transmission output: 10 mW
Note: The maximum radio range is up to 25 m indoors and up to 350 m in the open field.