TIMER-2H MODE
T

.

he "Timer 2h" mode can be used to quickly warm up the room or to speed up

-

mode

Press the [

]

button until the display shows the "2h" .

T

radiator

he device is activated at the maximum power for 2 hours, up to a maximum

temperature. The “Timer-2h” mode is automatically deactivated after a period of 2 hours
and the device returns to the

. The user can switch to another operative

Chrono mode

mode at any time by simply pressing the

button.

[

]

mode

IR controlled

operational mode and all related functions can also be set through the IR

remote control (optional).

4. PROGRAMMING

a) Set date and time
-

crono

Activate "Stand-by" mode and press the [

]

button for more than 5 seconds.

-With the

and

buttons, scroll through the menu to the Time function, press

to

[+]

[-]

[mode]

confirm.
- Day: The word "day" blinks for 2 seconds, with the

and

buttons select the Day and

[+]

[-]

confirm with the [mode] button.
- Time: Use the

and

buttons to select the time and confirm with the [mode] button.

[+]

[-]

- Minute: Use the

and

buttons to select the minutes and confirm with the [mode]

[+]

[-]

button. When finished, the thermostat will exit the programming menu.

b)Set programs for the Chrono mode (P1, P2, P3):

- Activate the "Chrono" mode using the

button press the

button to choose

[mode]

[Chrono]

which of the programs P1, P2, P3 to set.
- Hold the

button to set the time sequence.

[Chrono]

Now a time sequence can be set for each day of the week. It starts with day 1, the time zone
is displayed, the desired sequence is selected with the

and

buttons to select, for each

[+]

[-]

hour, the "Comfort" temperature (full bar) button

and the temperature "Night" (empty

[+]

bar) button

.

[-]

Press

to confirm the first day setting, repeat the same procedure for the remaining 6

[Mode]

days of the week; the setting of the day is stored and pressing the

button it will be

[Mode]

Selmo

Electronic

Via Pacinotti, 24 - 35030 Rubano

www.selmo.it

(PD) Italy- Tel 049.8976761, Fax 049.8976085 -

Selmo

Electronic

Via Pacinotti, 24 - 35030 Rubano

www.selmo.it

Rev.02 - June 2018

“Infinity PLUS”

Electronic control for electric radiators

Comfort technology division

Selmo

EN

Содержание Infinity PLUS

Страница 1: ...it to interface with the Selmo remote control Infinity is a certified product Infinity is according to direcrives Eco design Directive for Energy using Products 2005 32 EC 0 5W EN 60335 1 2012 A11 201...

Страница 2: ...ck ASC IR receiver 7 32 C 2000W 230Vac 50Hz 3 cables Neutral Grey Phase Brown Fil Pilote Black 2 cables Neutral Blue Phase Brown Plug Schuko Switzerland Italian English 2 female faston 6 3x08mm phase...

Страница 3: ...I If installed in rooms with bath or shower observe the protection zones in the United Kingdom according to the regulation for IEE wiring Also observe all local regulations must be protected by a 30mA...

Страница 4: ...stor only by personnel authorized Make sure that the heating element power does not exceed the power maximum required by the thermostat ATTENTION Disconnect the power supply before installation The in...

Страница 5: ...e respective housing of the thermostat 4 Push the cables into their housing in order to ensure correct fixing 5 Apply the plastic cover 6 do not rotate the device for more than 30 in both directions S...

Страница 6: ...that supports the Fil Pilote system The brown wire is the phase L the gray wire is the neutral N and the black wire is used for the reception of the Fil Pilote signal DO NOT connect the black wire to...

Страница 7: ...switched on it emits a sound lasting one second Mode Stand By Crono Antifreeze Night Comfort Fil Pilote Mode Current week day Crono mode daily program Crono mode selected program Setted hour or tempe...

Страница 8: ...unit 1 Press the mode button until the Fill Pilot icon is displayed 2 Set the desired temperature through the and The mode of operation will be selected by the Fil Pilot Control Center The device ope...

Страница 9: ...lic space To turn on off the keypad press the button for 5 seconds mode Adaptive Starting ControlASC This function if activated will turn on the radiator in advance of the programmed Max 2 hours to en...

Страница 10: ...and confirm with the mode button Minute Use the and buttons to select the minutes and confirm with the mode button When finished the thermostat will exit the programming menu b Set programs for the C...

Страница 11: ...nt for the recycling of electrical and electronic equipment Separate collection and recycling of the equipment at the time of disposal promotes the conservation of natural resources and ensures that i...

Отзывы: