TUNNEL SPIDER
16
Warning
If fuses keep blowing it may be an indication of a fault
of the electrical apparatus, in this case contact
Technical Support.
Thermal circuit breakers
These are located inside the electric panel and have the
task of preventing the overheating of the motors. When
one of these protections is activated, follow this procedure
to reset it:
- set the main switch to the OFF position;
- open the electric panel; every circuit breaker has a
button that springs out if the protection is activated.
To unblock it one must press the reset button located on
its side. If this does not stay pressed wait a few minutes
for the protection to cool down and then re-press the
button.
Protective plates
The machine is equipped with removable protective plates
(A) that can be removed with the appropriate tool, thus
allowing access to the internal parts of the machine for
maintenance procedures.
The machine also has fixed protective plates, held in place
by holding screws that can be loosened with the
appropriate tool. If the screws are removed the fixed
protective plates will not remain in place and must be
placed on the floor.
All the protective plates have smoothed and rounded
edges for the safety of the exposed individual and of the
operators.
Attention
Do not switch the machine on if the protective panels
are removed or not correctly fixed into position with
the appropriate screws.
Do not forget to remove cloths, keys or utensils used
for the maintenance operation from within the
machine. Before closing the protective panels and
switching on the machine check carefully and if
necessary remove any foreign objects which may be
present inside the machine.
2.5.
Client’s safety measures
The client must arrange for the following safety
measures to be in places:
Provision of an adequate location for installation,
paying particular attention to the characteristics below:
Adequate flooring
Normal and emergency lighting
Adequate ventilation
Clearly signposted emergency exits
Provision of mains voltage connection with
associated safety devices, conforming with the
norms in force and the characteristics of the
machine
Adequate means for the collection and subsequent
disposal of residues, even hazardous or special
ones (oils and grease, broken or waste material,
etc.).
Adequate fire safety systems and equipment
Prohibition of entry into the installation area to non
authorized personnel
The customer must also provide for:
Training of the operators and the maintenance
technicians
Training for the operators on the basic functioning
of the machine and emergency devices
Provision of personal safety equipment to protect
the operator and the hygiene of the product
Checking the qualifications of external maintenance
technicians potentially called to work on the
machine
Keeping of a maintenance log book
The employer is also responsible for checking that the
operators correctly carry out the procedures explained
in this manual.
Содержание SPIDER
Страница 1: ...A ...
Страница 2: ...TUNNEL SPIDER B ...
Страница 7: ...TUNNEL SPIDER 3 1 2 3 4 5 7 6 8 ...
Страница 12: ...TUNNEL SPIDER 8 Electronic Board ...
Страница 30: ...TUNNEL SPIDER 26 Configuration SPIDER MOULD LOADER 175 ...
Страница 37: ...TUNNEL SPIDER 33 7 ELECTRICAL DIAGRAMS ...
Страница 38: ...TUNNEL SPIDER 34 ...
Страница 39: ...TUNNEL SPIDER 35 ...
Страница 40: ...TUNNEL SPIDER 36 ...
Страница 41: ...TUNNEL SPIDER 37 ...
Страница 42: ...TUNNEL SPIDER 38 ...
Страница 43: ...TUNNEL SPIDER 39 ...
Страница 44: ...TUNNEL SPIDER 40 ...
Страница 45: ...TUNNEL SPIDER 41 ...
Страница 46: ...TUNNEL SPIDER 42 ...
Страница 47: ...TUNNEL SPIDER 43 ...
Страница 48: ...TUNNEL SPIDER 44 ...
Страница 49: ...TUNNEL SPIDER 45 ...
Страница 50: ...TUNNEL SPIDER 46 ...
Страница 51: ...TUNNEL SPIDER 47 ...
Страница 52: ...TUNNEL SPIDER 48 ...
Страница 53: ...TUNNEL SPIDER 49 ...
Страница 54: ...TUNNEL SPIDER 50 ...
Страница 55: ...TUNNEL SPIDER 51 ...