TROUBLESHOOTING

Error Codes 

Error

Reason

Solution

UUUUUU

1. Overload

2. Wrong connection with load cell

3. Load cell has quality problem

1. Reduce the weight

2. Check load cell connection

3. Inspect load cell; Check the input/output

4. See Q&A section

nnnnnnn

1. Calibration is no good

2. Wrong connection with load cell

3. Load cell has quality problem

1. Make sure scale is level

2. Check load cell connection

3. Check load cell input and output resistance

4. See Q&A section

ERR1

During calibration, weight is not used or 

the weight is above the max. capacity

Use correct weight within the defined range

ERR2

During calibration, the weight is below 

the minimum required weight

The calibration weight minimum is 10% of 

the max. capacity set in C04. 

Recommended to use 60%-80% of max. 

capacity if possible

ERR3

During calibration, the input signal is 

negative

1. Check all wire connections

2. Check load cell

3. Recalibrate

4. PCB replacement needed if steps 1-3 fail

ERR4

During calibration signal is unstable

After the platform is stable, start calibration

ERR5

EEPROM Error

Change PCB

ERR6

Exceed Zero Range

See Q&A section

ERR10

Scale was not stable when Zeroed

Wait for the scale to stabilize before zeroing

ERR11

Zero function can not be used in Tare 

mode

Go back to gross weighing, by pressing Tare 

then you can Zero

ERR12

Out of the zero range

Move the extra load

ERR15

Scale wasn’t stable when Tared

Tare once the load is stable

ERR16

Tared without a load

Add your load, then tare

ERR17

Out of tare range

Decrease the tare weight

ERR25

The record you are trying to check does 

not exist

Assure the record you are trying to check 

exists

ERR30

Printing format wrong in accumulative

weighing mode

Set Printing format to setting “2”

ERR31

Working mode wrong in accumulative 

weighing mode

Set Working mode setting to either “2 or 4”

ERR32

You are weighing over max. capacity

or you tried to print while the scale was 

unstable

Reduce weight on the scale

Print after scale has stabilized 

ERR33

Display Error, Printing with the indicator 

in accumulative weighing mode

Print the total weight after accumulating the 

weight of axles

ERR34

Printing error in normal Weighing mode

Wait for the load to be stable, then print

ERR35

Printing format wrong in normal weighing 

mode

Set Printing format to Setting “1”

Содержание SL-7561

Страница 1: ...www selletonscales com SL 7561 INDICATOR USER S MANUAL Portable Static Weighing Indicator...

Страница 2: ...rameters 2 Specifications 3 Power Supply 3 Displays 4 Display and Key Descriptions 5 Operating Instructions 6 7 Calibration 8 Indicator Parameter Settings Weighing Printing Mode Print Format Connector...

Страница 3: ...s it could damage the load cell inside Material that has a static electric charge could influence the weighing Discharge the static electricity of the samples if possible Another solution to the probl...

Страница 4: ...entage of the total weight Manual and automatic printing modes Date and time can be set easily Can connect to a PC or printer for data logging Wireless capability optional Splash proof keyboard and di...

Страница 5: ...prevent damage to your indicator When you use the internal battery for the first time you should charge the battery fully to prevent low voltage resulted from self leakage of battery If the battery is...

Страница 6: ...4 SL 7561 DISPLAY...

Страница 7: ...1 Print data 2 Works with the switch button to enter the calibration menu Total Shows you are in Accumulation mode The scale is at zero The scale is stable Net Shows you are in Net weight mode without...

Страница 8: ...o see the current change in weight not the entire amount of weight that is on the scale When the indicator is in normal gross mode pressing the TARE key will Tare the current weight on the scale and e...

Страница 9: ...tween the total weight and each individual pad scale weight Individual pad display shows the percentage of that pads load of the total weight Print If the weight on the scale is stable press the PRINT...

Страница 10: ...rameter if no errors 10 The display will show SPAN 0 use the STORE key to change to SPAN 1 press the PRINT key to select and enter the calibration setting 11 Use the arrow keys to enter the weight of...

Страница 11: ...save and exit settings at any time F 1 Menu Setting working mode unit decimal graduation and capacity Step Parameter Display Settings Options Enter F1 Menu F 1 1 Mode Mode 2 Choose how many weighing...

Страница 12: ...move on to the Saving parameter Select 1 and press print to save your calibration settings 9 Save SAVE 0 0 do not save calibration 1 save calibration F 3 Menu Step Parameter Display Settings Options E...

Страница 13: ...Menu Step Parameter Display Settings Options Enter F4 Menu F 4 22 Records S 0560 Set how many records weights you want your indicator to store Max the indicator can store is 2000 cps 23 PCB HE 1 0A P...

Страница 14: ...ing pads connected to the indicator to weigh an airplane 1 The pads should connect with LFW LRW RRW interfaces 2 Parameter settings F1 Working Mode setting 3 ModE 3 F3 Printing Format setting 1 PF 1 3...

Страница 15: ...2 F3 Printing Mode setting 0 PM 0 F3 Axle Number setting 3 ALE 03 3 Measure spacing between tire sets in an axle and place weighing pads accordingly 4 Drive the first axle of the truck on the weighing...

Страница 16: ...xle1 842 5kg RRW 293 0kg Axle1 842 5kg Operator Axle2 612 0kg LRW 319 0kg Gross 842 5kg RRW 293 0kg Operator Gross 1041 0kg Axle2 612 0kg Operator Gross 1454 5kg Operator Accumulative Printing Format...

Страница 17: ...icator will not function properly Please use the following table to connect your pads correctly INNER TERMINAL BLOCK CONNECTION DIAGRAM Weighing Pad Load Cell Connection Weighing Mode 1 LFW Mode 1 Set...

Страница 18: ...LF S 1 S 2 S 3 Data S 4 S1 weight status ST standstill US not standstill OL overload S2 weight mode GS gross mode NT net mode S3 weight of positive and negative or S4 kg or lb Data weight value includ...

Страница 19: ...place lid To Replace Paper Remove lid then squeeze and pull forward on the pull tabs to pull printer forward from indicator Carefully remove ink cartridge If the paper roll is not empty use the feed b...

Страница 20: ...RR5 EEPROM Error Change PCB ERR6 Exceed Zero Range See Q A section ERR10 Scale was not stable when Zeroed Wait for the scale to stabilize before zeroing ERR11 Zero function can not be used in Tare mod...

Страница 21: ...19 CONTACT US Please e mail info selletonscales com for any sales related questions or call 844 735 5386 Don t forget to visit our website at www selletonscales com...