![SellEton Scales SL-720 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/selleton-scales/sl-720/sl-720_installation-manual_1237075006.webp)
(844)-735-5386
www.selletonscales.com
SL-720
INSTALLATION MANUAL - WEIGHING KIT
CALIBRATION PROCEDURE
1. Turn on the scale by holding ON/OFF for 2 seconds.
2 Press HOLD and PRINT together to access the setup menu.
3. If done correctly, the display should now show
C 0 1
.
4. Press PRINT to access the C1 channel. The display should show
[
C I
#
].
5. Press ZERO to choose which unit you want to calibrate in (1 = kg, 2 = lb).
6. Press PRINT to set the value. The display will now show
C 0 2
.
7. Press PRINT to access the C2 channel. The display should show
[
C 2
#
].
8. Press ZERO to change the setting to the decimal places desired (The C2 channel is used to
adjust the decimal point on the scale. A value of 1 means there is one digit behind the decimal
point.)
9. Press PRINT to set the value. The display will now show
C 0 3
.
10. Press PRINT to access the C3 channel. The display should show
[
C 3
#
].
11. Press ZERO to cycle through the values until the desired graduation appears. (The C3 channel
adjusts the divisions on the scale. A value of 1 selected and C2 set to 1, the scale will read in 0.1 lb.
increments.)
12. Press PRINT to set the value. The display will now show
C O 4
.
13. Press PRINT to access the C4 channel. The display will show
[
######
].
14. Enter in the maximum capacity you want to use for this scale by using UNIT
and COUNT to
move the cursor left and right, and TARE and ZERO to move the values down and up. (The C4
channel is used to enter in the max capacity of the scale; Make sure this doesn't exceed the max
capacity of the scale; Max capacity divided by the increment set in C02 and C03 above cannot
exceed 5000.)
15. Press PRINT to set the value. The display will now show
C 0 5
.
16. Press PRINT to access the CS channel. The display should show
[
C 5 0
].
17. The CS channel calibrates zero on the scale. Make sure the scale is empty.