SellEton Scales SL-720 Скачать руководство пользователя страница 3

[email protected]

(844)-735-5386

www.selletonscales.com

FOR WOODEN PLATFORMS

Step 1:

 Make sure the wooden platform you've built – or are in the process of building – can withstand

the maximum weight you'll put on it.

Step 2: 

Turn the platform upside down.

Step 3:

 Drill 2 holes ( Same size & spacing between the holes as the mounting block. Use the mounting

block to draw out the holes first & then drill. Ultimately they need to match up to the load cells, be sure

to take time to do it correctly. this can impact readings if load cells are not positioned correctly.

NOTE:

 At all four corners of the platform (x 2 holes should be drilled on every corner). Each hole should

be drilled as close to its respective edge as possible. You need to purchase longer bolts for thicker

platforms. Measure the mounting block & load cell along with the thickness of the platform &

purchase the correct length of bolts. so that the load cell, mounting block & the platform are all

connected firmly.

Step 4: 

Use the 1/16" load spacers to bolt the load cells onto the platform. The spacers should be placed

between the load cell & the mounting block. This is necessary to give the load cells adequate room for

accurate readings. ( refers to the picture in this manual)

Step 5:

 Take out the junction box. See the below diagram to understand where each of the 4 load cell

cables will need to go into the junction box.

SL-720 

INSTALLATION MANUAL - WEIGHING KIT

OVERALL INSTALLATION

Содержание SL-720

Страница 1: ...ce platform not included with the kit This weighing kit is mostly used for floor scale livestock scale applications or to turn any object platform into a scale with Maximum capacity of 10 000 lbs You...

Страница 2: ...g block x 4 load cell Mounting blocks typically welded to steel structures or bolted to wood x 8 Hexagon bolts x 8 washers x 8 lock washers x 1 Junction Box Plastic or Stainless steel x 1 Quick Connec...

Страница 3: ...be drilled on every corner Each hole should be drilled as close to its respective edge as possible You need to purchase longer bolts for thicker platforms Measure the mounting block load cell along w...

Страница 4: ...the mounting block ensure that all blocks are positioned in the same way with the feet of the load cell located in the corner of the platform not facing inside the platform Picture below demonstrates...

Страница 5: ...refer to the diagram below for the indicator cable load cell wiring SL 720 INSTALLATION MANUAL WEIGHING KIT CAPACITY ACCURACY CHOICES 1000 lb Capacity x 2 lb Accuracy 2500 lb Capacity x 5 lb Accuracy...

Страница 6: ...ow C03 10 Press PRINT to access the C3 channel The display should show C3 11 Press ZERO to cycle through the values until the desired graduation appears The C3 channel adjusts the divisions on the sca...

Страница 7: ...n weight Single Point Calibration 20 Press PRINT to continue The display will now show C06 21 Press PRINT to access the C06 channel The display will show C6 0 22 The C6 channel is used to calibrate th...

Страница 8: ...3 Check load cell input and output resistance 4 See Q A section 1 Calibration is no good 2 Wrong connection with load cell 3 Load cell has quality problem During calibration weight is not used or the...