Firmware update
The firmware in CCM 164 can be updated using the PC programme “Selektro Firmware Updater” for
Microsoft Windows 7 or later, and a Micro USB cable for connecting between a PC and CCM 164:
It is important to make a backup of your settings before starting the firmware update. I.e. programmed
phone numbers, messages and other settings.
This is important because it might be necessary to reset
the configurations after updating the firmware
.
1.
Start the PC programme “Selektro Firmware Updater”.
2.
Now connect the Micro USB cable between the PC and CCM 164.
3.
Hold down the Mode button until the program displays an SN number (approximately 20
seconds):
Correct example not connected yet
If this method doesn’t work:
a.
Send the command “#sys restart”
b.
Remove the supply to the module. Wait until the backup supply is completely discharged
(all LEDs are off), which can take up to 20 minutes.
Now unplug it and plug it in again