![Selektro CCM 164 Скачать руководство пользователя страница 32](http://html.mh-extra.com/html/selektro/ccm-164/ccm-164_user-manual_1236924032.webp)
CCM 164
–
User Manual
–
GB / UK
32
#sys defaults
Configures all values to factory settings
#sys restart
Restarts the module
‘No answer’
NB: The function forces the module to restart, i.e. recently updated service information (see section
”) is not guaranteed to be saved at startup again.
#sys info
Example:
Retrieve system information
Module name = “
Module 12
” [the return is blank if there’s nothing].
Uptime = “2d 23:59:59” [the time the module has been on for in days
hours:minutes:seconds].
Product = “
CCM164 - GSM-
230V” [the product’s name and model type].
Firmware version = “FW &v2.1.0&” will be read as version 2.1.0.
Language = “EN”, for English.
Text memory used = “mem:78/1100” [used 78 out of 1100 characters].
LOG memory used = “Log:8/27” [used 8 out of 27 LOG places].
Speci
al functions = “F=0000” [special functions selected]
Lock level = “Lock0 (User)” [the level and the access level of the phone number].
Module clock = “Clock:09:30D3” [time in the module and day of the week 1
-7 (Mon-Sun)]
#sys iostat
Example:
Show values for all inputs and outputs
NB: Reminds about “#I ?”
#sys defaults
OK: Sys Defaults
#sys restart
#sys info
Module 12. 2d 23:59:59 CCM164 -
GSM-230V FW &v2.1.0& EN.
mem:78/1100 Log:8/27 F=0000 -
Lock0 (User) Clock:09:30D3
#sys iostat
AI1=OFF I1=2bar I2=4m I3=OFF
I4=OFF I5=OFF I6=OFF Q1=OFF
Q2=OFF Q3=OFF Q4=OFF
Содержание CCM 164