![SELECTRONIX SLC4075 Series Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/selectronix/slc4075-series/slc4075-series_installation-and-operating-manual_1236921010.webp)
www.selectronix.us
Selectronix, Inc.
(425) 788-2979
SLC4075 TouchScreen Gateway Installation & Operating Manual
___________________________________________________________________________________________________
10
vii.
See “Status”
1.
“Writing device firmware block nnnn”, where nnnn is approximately
2.
“Do not power off the target device during this process.”
viii.
TIP: A convenient way to set the time on the TSGW is to select
Link;Set Time.
Configuration Complete.
Configuration using SD Card
The CR1000 TSGW may upload a new image by using an SD card (SLC4030)) inserted into the unit.
Obtain an SD card with the desired image from Selectronix or
•
On a PC using the Crimson software, loaded with the desired database
o
Save the image on the SD card using File; Save Image;
image.ci3 (must be this name)
o
Tip: Save a copy of the source database on the SD card for later identification of the
database image contents.
•
For CR1000 models
: (See back of TSGW for model identification)
o
Insert the SD card into the unit.
o
Power up the TSGW.
•
For G307 Model
:
o
On the TSGW, power off and open the DIP switch access cover on the back of the unit.
o
Set switches 1 and 2 to On (Up)
o
Power up the unit and see the System Menu screen
o
Press and hold the <button> until it changes color
o
<Database Utilities>
o
<Database Image Menu>
o
<Load Image from Memory Card
o
Load Database Image from Memory Card…
o
Are you sure you want to continue?
o
<Yes>
o
See the unit reboot
o
<Continue>
o
Reset DIP switches to continue
o
Power off the unit and set the DIP switches back to normal SW1 and SW2 off(down)
o
See the new database load and run
•
Configuration Complete
3.
Terminology
Acronym
Definition
ADC
Analog-to-Digital Converter
AUX
Auxiliary SLC4000 direct connection to the Step command or Load Limit inputs.
BMI
Building Management Interface
BMS
Building Management System
DDC
Direct Digital Control
DIP
Dual Inline package
DeciPct
Percent in tenths – 10% is represented as 100
GPAx
General Purpose Analog Channel x
GPDI
General Purpose Digital Input
GWnet
Gateway net may be BACnet or Modbus on Ethernet or serial
MAC
Media Access Control
PGW
Process Gateway SLC4060
RTDx
Resistance Temperature Device x
Rx
Receive
S4K
SLC4000
SLCnet
Selectronix communications via RS485
TSGW
TouchScreen Gateway SLC4075-x
Tx
Transmit