Selectronic Australia LD250-24 Скачать руководство пользователя страница 3

Portable Use 

Batteries and Connections 

By using optional battery clips, the LD250 can be connected directly to a 
vehicle battery. When using Alligator clips ensure they have a tight grip 
around the battery post. Wherever possible battery connections should be 
bolted. If connecting the LD250 through a cigarette lighter socket the 
maximum power output of the LD250 will be 

severely

 restricted, this 

practice should be avoided. Check with your supplier or installer if you are 
unsure.

 

Batteries are the key to maximum performance from your LD250, if a 
battery is too small or not fully charged it may result in de-rated 
performance from your LD250.

 

Battery ratings 

Batteries can be rated in one of two ways: 
1.

 

CCA = Cold Cranking Ability. This is the amount of power or current that 
a battery can deliver for a short period, typically a few seconds. This how 
a car battery would normally be rated. 

 
Do not use alligator clips in a moving vehicle 

 

Auxiliary Battery

Earth (to chassis)

LD250 Inverter

Isolator

Vehicle
Alternator

 

2.

 

Ah = Ampere Hours. This is the maximum amount of energy that can be 
stored in a battery; this figure will generally be stated at a particular hour 
rate. This is how a deep cycle or storage battery would normally be rated. 

Start Battery

Earth (to chassis)

 

By incorporating an auxiliary battery in the manner above, the starting battery 
should remain charged for vehicle starting (see your auto electrician). 
The LD250 has sufficient battery cable length to allow it to sit underneath the 
vehicle whilst in use. If the ground is wet, place the LD250 on a waterproof 
liner. 

Selectronic Australia 

 

LD250 Manual

 

100Ah @100hr, this means that when this battery is discharged over 
a period of 100 hours, the battery has a capacity of 100Ah. This in 
theory means 1 Amp for 100 hours, although this would in practice 
result in a totally discharged battery that may not then recover. 

 

 

To achieve maximum performance from your LD250 you must have a 
battery capable of delivering 25 Amps for a short period whilst 
maintaining at least 21.0 volts. To increase the capacity of your battery you 
may need to join more than one battery together.

 

 

 

Where batteries are joined 
in 

series

, add the voltage of 

each battery. 

 
 
 

The capacity will equal the capacity of the smallest battery. 2 x 12 
Volt 100 Ah batteries connected in series would have a total 
capacity of 24 Volts – 100 Ah.  

 
 

 

Selectronic Australia 

 

LD250 Manual

 

Содержание LD250-24

Страница 1: ...nts Page No Introduction 1 Warranty Card 1 Installation 1 Batteries and Connections 4 Getting Started Quickly 6 Parts Identification 6 Operation 7 STATUS Indicators 7 Maintenance 8 Inverter 8 Batteries 8 Radio Frequency Interference 9 Fault Finding 10 Product Warranty Conditions 11 Specifications 12 Selectronic Service Network 13 Legend for Symbols Warnings and electrician s notes Hints and Pointe...

Страница 2: ...about our product that will not fit on the warranty card please feel free to drop us a line Yes constructive criticism will also be welcome Warning As a matter of safety Selectronic strongly recommend that all fixed installations be designed and installed by appropriately qualified person The Solar Energy Industries Association in your state or territory can provide names of accredited system desi...

Страница 3: ...ttery this figure will generally be stated at a particular hour rate This is how a deep cycle or storage battery would normally be rated Start Battery Earth to chassis By incorporating an auxiliary battery in the manner above the starting battery should remain charged for vehicle starting see your auto electrician The LD250 has sufficient battery cable length to allow it to sit underneath the vehi...

Страница 4: ...ning batteries together How long will my battery last To work out how long your battery will last follow this basic guide This guide presumes commencing with a fully charged battery Take the total rating of the appliance being run 1 light globe 25watts 1 20 inch TV 67watts 1 VCR 30watts 9 LED 1 will illuminate If no LEDs light check for correct connection to battery 10 You re away LD250 Parts Iden...

Страница 5: ...due to high battery voltage then LED 2 will stay ON When the battery voltage is reduced LED 2 will turn OFF and the inverter re activate LED 3 Over temperature AC Overload Permanently ON If the inverter shuts down due to internal components getting too hot then LED 3 will come ON and will remain ON until the temperature has dropped to a safe level LED 3 will then turn OFF and the inverter re activ...

Страница 6: ...rd means RFI is low but how well the inverter performs in a particular installation can vary Below are some suggestions to help reduce the effects of RFI in your installation This is more than likely caused by high battery volts during peak charging times from Solar Panels Battery volts should never exceed 34 volts If this is the case have your Solar Regulator checked It is recommended that the po...

Страница 7: ...ed in this manual There will be no charge for the return of the inverter Outside Australia New Zealand Product purchased for use outside Australia New Zealand must be returned to Selectronic Australia s Service Centre to enable warranty claims to be processed Freight cost to be borne by the customer No charge will be made for the product return Current draw from Battery Condition Amperage Inverter...

Страница 8: ...0 Australia Australia Ph 02 9606 0279 Ph 02 6689 1430 Fax 02 6689 1109 Reid Technology Ltd 3 5 Auburn Street Solar Inverter Services Takapuna 13 Thirteenth Ave North Shore City Sawtell Auckland NZ NSW Ph 9 489 8100 2452 Fax 9 489 8585 Ph 02 66581733 ps reidtechnology co nz Part No ST M LD250 REV 3 17 02 2004 SELECTRONIC AUSTRALIA 25 Holloway Drive Bayswater Victoria 3153 Australia Phone 03 9762 48...

Отзывы: