System Controller Programming Instructions
To be used in conjunction with the Controller Programming Instruction.
By setting all
FUNCTION
switches to
ON
and then pressing enter will set the system to
default. (See System function Programming for set up and manufactures default settings).
Select the line number to program using the
FUNCTION
switches 1 - 5, note that position 6,
7 and 8 are always in the
OFF
position. (See
Controller Programming Instruction).
Next using the
DATA
switches 1 to 4 set the Privacy time. For Call volume and Call type, set
DATA
switches 5, 6 and 7 to the required positions. At this time, setting
DATA
switch 8 to
the
ON
position will program a Strobe, Sounder or both. (See
Controller Programming Instruction
).
Finally pressing the enter button will save the current Line information to memory. Continue until all
Lines are programmed.
Use the
FUNCTION
switches to select Entrance Panel 1 and the
DATA
switches to select
the number of seconds for the release duration. Select the lock release duration time using the
TIME SELECTION
seconds chart. (See
Controller Programming Instruction
).
Repeat for Entrance Panel 2
Use the
FUNCTION
switches to select Entrance Panel 1 and the
DATA
switches to select
the number of seconds for the ringing time duration. Select the ring time duration using the
TIME SELECTION
seconds chart.(See
Controller Programming Instruction
).
Repeat for Entrance Panel 2
Use the FUNCTION switches to select Entrance Panel 1 and the DATA switches to
select the number of seconds for the call duration time. Select the call duration time using the
TIME SELECTION seconds chart. (See
Controller Programming Instruction
).
Repeat for Entrance Panel 2
Use the FUNCTION switches to select Entrance Panel 1 and the DATA switches to select
the number of minutes for the delay time. Select the Door Alarm delay duration time using the
TIME SELECTION minutes chart. (See
Controller Programming Instruction
).
Repeat for Entrance Panel 2
Use the FUNCTION switches to select Entrance Panel 1 and the DATA switches to select
the number of minutes for the alarm duration. Select the Door Alarm duration time using the
TIME SELECTION minutes chart. (See
Controller Programming Instruction
).
PROGRAMMING LINES
LOCK RELEASE PROGRAMMING
T
ELEPHONE RING TIME FROM THE ENTRANCE PANEL
ENTRANCE PANEL TO TELEPHONE CALL DURATION TIME
DELAY BEFORE DOOR ALARM ACTIVATION
DOOR ALARM DURATION TIME
Repeat for Entrance Panel 2
If required, the System Controller can send serial data to a PC.
- 15 -
Functional Video
Installation Manual
Functional Video
Revision 1.8 Date: 10/03/2009