background image

 

GENERAL: 

All transfer units come standard with an Auto shut-off gun and all pumps feature a duty cycle for 30 

minutes of  continuous  dispensing,  all  pumps  also  contain  an  internal  bypass  that  allows  for the 
pump to operate for up to a maximum of three minutes when the filling nozzle shuts off  without 

damaging the pump or motor. 

SPECIFICATIONS: 

TANKS: 

Made  from  impact  resistant  polyethylene,  UV  stabilized,  coloured  grey  and  fitted  with  lid  and 

breather with a 200L, 300L or 400L or 600L capacity. Depending on the model of diesel transfer unit, 

tank styles will vary as well as some features. 

-

 

300L

 

DIESELPAK (SQUATPAK) Features 

Large non-lockable breather cap, large internal baffle 

-

 

400L CUBE Features 

Lockable filler cap with 2 keys, internal baffle, forklifting points for tanks when empty, tank 

fill gauge, large pump cover suitable for neatly containing hose and gun and lock to secure 

all contents of diesel transfer unit. 

-

 

200l, 600L CUBE Features 

Polytuff tank, U.V. stabilized and impact resistant with breather vent. Forklifting provision 

(for moving tank when empty). Lockable pump cover 

 

GUN: 

Trigger filling nozzle with automatic shut-off and hose swivel. 

DELIVERY HOSE: 

4m x

 

¾” Diesel Delivery hose supplied. 

FILTRATION: 

Suction foot screen filter. 

PUMPS: 

IMPORTANT OPERATIONAL NOTE-

 The internal Bypass fitted in all diesel pump models is designed 

to protect the pump and motor from damage when the trigger is shut off for a time no greater the 

2-3 minutes.  

This is enough time for the operator to switch off the pump or recommence pumping.  
When the nozzle is off and the pump is running the pump pressure increases and the electric motor  

load increased using more power (amps) which in turn generates more heat within both the pump 

and motor,  risking increased wear or possible if the pump is not switched off. 

DIMENSIONS AND WEIGHTS: 

Mass is specified with tank empty. To roughly calculate gross mass, add 1 kg/liter capacity. (e.g. 200L 

=200Kg). All dimensions are in mm, Mass in Kg, the mass of each tank may vary according to the 
type of pump fitted and other 

accessories.  

 

 

Power 

Output 

Volts 

Amps 

Open Flow 

Motor Duty 

Cycle 

Internal 

Bypass 

Power Cord 

RPM 

Internal 

Fuse 

280W 

12V DC 

22 

amp 

40L/min 

30 minutes 

Yes 

4m with alligator 

clips 

2600 

25 amp 

Product Code 

Tank Capacity 

Length 

Width 

Height 

Mass 

Hose Length 

SQDS200-7 

200L 

800mm 

660mm 

625mm 

28kg 

4m 

SQD300-7 

300L 

1060mm 

900mm 

530mm 

30kg 

4m 

SQDS400-7 

400L 

1110mm 

960mm 

660mm 

46kg 

4m 

SQDS600-7 

600L 

1140mm  1350mm  675mm 

55kg 

4m 

Specifications 

Содержание DIESELPAK 300

Страница 1: ...0L SQDS200 7 SQD300 7 SQDS400 7 SQDS600 7 VICTORIA HEAD OFFICE Telephone 61 03 9215 2700 Fax 61 03 9215 2701 www silvan com au NEW ZEALAND Hamilton New Zealand Telephone 64 07 8496 033 Fax 64 07 8496070 www silvannz co nz SILVAN AUSTRALIA PTY LTD ABN 48 099 851 144 ...

Страница 2: ...not cover Conditions resulting from misuse use of incompatible chemicals exceeding machine specifications including overloading impact damage negligence accidental damage or failure to perform recommended maintenance services as specified in the Owner Operator Manual applicable to the product Damage caused by continued use of a product after initial failure Any product which has been repaired by o...

Страница 3: ...ansported on a vehicle Warning This Diesel unit should not be lifted when partially or completely full unless supported by an appropriate frame or pallet Warning This unit should never be left unattended while dispensing or being filled Warning Before attempting to fill the tank at a service station consult the operator for the correct procedure Warning Do not store the diesel unit within or next ...

Страница 4: ...fety decals before operating the unit Failure to comply with these warnings could result in serious injury or death Safety decals should be kept clean and legible at all times If any decals are missing or unreadable they should be replaced by ordering new decals from your Silvan dealer using the part numbers shown Warning decal part number DEC48 Safety Instructions cont ...

Страница 5: ... hose swivel DELIVERY HOSE 4m x Diesel Delivery hose supplied FILTRATION Suction foot screen filter PUMPS IMPORTANT OPERATIONAL NOTE The internal Bypass fitted in all diesel pump models is designed to protect the pump and motor from damage when the trigger is shut off for a time no greater the 2 3 minutes This is enough time for the operator to switch off the pump or recommence pumping When the no...

Страница 6: ...r to bleed from the hoses after a short time the pump will have primed and delivery will commence We recommend for this first priming that the lid is removed from the tank and the nozzle is directed back into the tank while pumping to avoid spillage or loss of Diesel with this done the unit is now ready to operate To dispense the pump must be turned on and the nozzles trigger depressed the nozzle ...

Страница 7: ...rts Remove the end cover of the pump by first unscrewing the three Socket Head screws and lifting off the cover Clean the impeller vanes ensuring you remove any dirt particles caught between the ends of the vanes and the impeller housing Do not over tighten head screws when reassembling Pump stalls when Transfer Gun trigger is released and pump is running The non return valve in the outlet of the ...

Отзывы: