background image

 

Specifications 

 

Engine 

Model 6.5Hp 
Single cylinder 196cc 4-stroke OHV petrol with 
forced air cooling and electronic ignition. 
Dual element dry air filter. 
Manual recoil rope start. 
Max power  

4.8kW (6.5HP) at 3600 rpm 

Noise level 

82dBA at muffler side 

 

Fuel Tank

  

Capacity 

 

3.6 litre 

Operating duration 

2 hours approx. 

 

Frame   

Welded tubular steel.

  

 

Pump 

Direct coupled centrifugal impeller type    
Operating speed 

3600 rpm 

 

Model LBA-113 Fire Pump, 1stage 

Max Output -Open flow  380 l/min 

 

Max Pressure-No Flow  5 Bar (72psi) 50m 
Suction lift height 

3.0 metres 

Inlet connection  

1.5 inch BSP (38 mm) 

Outlet connections 

2 X 1 inch BSP (25 mm) 

 

 

 

1 X 1.5 inch BSP (38mm) 

 

Model LBA-100 Fire Pump, 2 stage 

Max Output -Open flow  250 l/min 

 

Max Pressure-No Flow  7 Bar (100psi) 70m 
Suction lift height 

3.5 metres 

Inlet connection  

1.5 inch BSP (38 mm) 

Outlet connections 

2 x 1.0 inch BSP (25 mm)

 

 

 

1 x 1.5 inch BSP (38 mm) 

 
Model LBA-102 2” Transfer Pump 

Max Output -Open flow  460 l/min 

 

Max Pressure-No Flow  2.2 Bar (32psi) 22m 
Suction lift height 

3.0 metres 

Inlet connection  

2 inch BSP (50 mm) 

Outlet connections 

2 inch BSP (50 mm) 

 

Model LBA-103 3” Transfer Pump 

Max Output -Open flow  800 l/min 

 

Max Pressure-No Flow  2.4 Bar (37psi) 24m 
Suction lift height 

3.0 metres 

Inlet connection  

3 inch BSP (75 mm) 

Outlet connections 

3 inch BSP (75 mm) 

 

 
 
Overall Dimensions  

(mm, kg) 

Length  Width   Height  Weight 

 LBA-113 

460 

375 

395 

30 

 LBA-100 

460 

375 

395 

30 

 LBA-102 

470 

380 

400 

27 

 LBA-103 

510 

380 

485 

30 

 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание LBA-100

Страница 1: ...Operator s Manual MANLBA 100 Rev E 3 10 07 Selecta Power Pump Units 6 5 HP Fire Pump 1 stage 6 5 HP Fire Pump 2 stage 6 5 HP Transfer Pump 2 6 5 HP Transfer Pump 3...

Страница 2: ...are has been taken to make it as complete and accurate as possible The information illustrations and technical data were considered to be correct at the time of preparation In accordance with our poli...

Страница 3: ...he pump s operation maintenance and safety procedures Now that you are a proud Silvan owner all our services and dealer support are available to you should you need them We assure you of our best atte...

Страница 4: ...25 mm 1 X 1 5 inch BSP 38mm Model LBA 100 Fire Pump 2 stage Max Output Open flow 250 l min Max Pressure No Flow 7 Bar 100psi 70m Suction lift height 3 5 metres Inlet connection 1 5 inch BSP 38 mm Out...

Страница 5: ...misuse use of incompatible chemicals exceeding machine specifications including overloading impact damage negligence accidental damage or failure to perform recommended maintenance services Any produc...

Страница 6: ...pump in a well ventilated and well lit area that is free from flammable or other materials that may interfere with its safe operation Never operate in an enclosed area as engine exhaust fumes contain...

Страница 7: ...eration the water supply is exhausted stop the engine immediately and fill the pump once it cools down Engine Pre Starting Checks 1 Oil Level Caution The engine is shipped without oil It must be fille...

Страница 8: ...on Set the throttle to the full open position to obtain maximum pump output If necessary the flow rate can be regulated by adjusting the throttle position Stopping the Engine To stop the engine under...

Страница 9: ...ber Clean After every 500 hours 3 Fuel tank strainer Clean O 3 Fuel supply pipe Check Every 2 years replace if necessary 3 Pump impeller Inspect O 3 Pump housing Inspect O 3 Pump inlet valve Inspect O...

Страница 10: ...on the air cleaner base making sure the gasket is in place Tighten the lower wing nut firmly then install the air cleaner cover and tighten the upper wing nut Fuel Sediment Cup Move the fuel valve to...

Страница 11: ...hy storage it is best to drain the fuel tank into a suitable container by setting the fuel valve to on and removing the sediment cup and the drain plug from the carburettor Reinstall the sediment cup...

Страница 12: ...LTD ABN 48 099 851 144 Melbourne Australia Telephone 61 03 9887 2788 Facsimile 61 03 9887 1035 www silvan com au SILVAN NEW ZEALAND PTY LTD Hamilton New Zealand Telephone 64 07 8496030 Fax 64 07 84960...