background image

Version 2 Short Form: December 2008 

FOCUSING 

Standard Yoke Model:

 

The variable beam of the Rama is altered by adjusting the position of the lamp / reflector 

assembly relative to the lens. Finger tight pressure only is necessary to lock the lamp / reflector assembly off in the chosen 
positions. A beam angle reference scale is provided to prefocus the luminaire if desired. When focusing, first spot the beam 
down, position the luminaire and then flood the beam to cover the area required. The beam can then be shaped using the 
barndoors (Order Code: 20BDSF12). 
 

FFT Yoke Model

:  The variable beam of the Rama is altered by adjusting the position of the lamp / reflector assembly 

relative to the lens. The Rama is suppled with an FFT focus assembly to facilitate fast adjustment. To adjust the beam angle of the Rama, squeeze 
the focus grip and slide to the position required. Release the focus grip to lock the focus.  A beam angle reference scale is provided to prefocus the 
fixture if desired. When focusing, first spot the beam down, position the fixture and then flood the beam to cover the area required. The beam can 
then be shaped using the barndoors. 
 

YOKE PIVOT ADJUSTMENT 

The yoke on the Rama range can be positioned anywhere in the channel that runs the length of the luminaire. This is useful to achieve the best 
balance if using a colour changer or other accessory mounted on the front of the fixture, or to fit the luminaire in space restricted positions. The yoke 
balance point is factory set on the lamp house for normal applications.  To move the yoke, loosen the M8 bolt at the bottom pivot point of the yoke on 
the right side of the luminaire.  Release the tilt locking clamp on the left side of the luminaire, and slide the yoke to the required position. Check the 
yoke is evenly positioned on each side and tighten the M8 bolt, and the tilt locking clamp. 
 

PAN AND TILT ADJUSTMENT  

Standard Yoke Model:

 

To pan your luminaire, loosen the yoke nut and bolt holding the hookclamp onto the yoke and adjust the yoke as 

required, then retighten the yoke nut and bolt. The nylock nut that secures the yoke on the opposite side to the tilt handle sets the tilt lock friction. 
The tilt friction can be adjusted by loosening or tightening up the nylock nut. To tilt your fixture, turn the tilt lock knob clockwise, tilt the luminaire to 
the position required, and then turn the tilt lock knob anticlockwise. A tilt angle reference scale is provided on the locking clamp disc to prefocus the 
luminaire if desired. 

 

Please note that as the handles and integrated safety bond on the Rama range can reach high temperatures depending on the position or orientation 
of the fixture, and that gloves should always be worn when focusing these fixtures. 
 

FFT Yoke Model:

  The Rama is suppled with a FFT pan assembly on the yoke to facilitate fast adjustment. To pan your fixture turn the pan locker a 

¼ turn clockwise and adjust the yoke as required, then turn the pan locker a ¼ turn anticlockwise to set the position. A pan angle reference scale is 
provided on the FFT pan assembly to prefocus the luminaire if desired. The nylock nut that secures the yoke on the opposite side to the tilt handle 
sets the tilt lock friction. The tilt friction can be adjusted by loosening or tightening up the nylock nut. To tilt your luminaire, turn the tilt lock knob 
clockwise, tilt the luminaire to the position required, and then turn the tilt lock knob anticlockwise. A tilt angle reference scale is provided on the 
locking clamp disc to prefocus the luminaire if desired. 

 
ACCESSORIES 

Suspension Hook Clamp (Order Code: 20HC)          

 

 

Safety Chain (Order Code: 20SC)  

Lens Safety Mesh (Order Code: 20SM6)  

 

 

 

Barndoor (Order Code: 20BDSF12) 

Colour Frame – the fixtures is supplied with a colour frame 7 3/8” x 7 ½”. Additional colour frames are available (Order Code: 20CFRA12). 
 

SAFETY & MAINTENANCE 

Selecon has manufactured this luminaire in accordance with recognised best practices to recommended international safety standards.  It is your 
responsibility to maintain this luminaire in good and safe working condition. Repairs should only be carried out by suitably qualified persons.  Do not 
operate the luminaire with cracked lens, damaged cables etc. Consult your Selecon distributor for assistance.  Only replace damaged parts with 
authorised Selecon spares. N.B. luminaire cable – your Selecon luminaire is fitted with a special heat-resistant, flexible cable, replace with genuine 
Selecon spare part cable kit only – refer to your Selecon distributor. (Replacement cables are supplied complete with necessary terminal 
connectors). 
 
Cable Conductor colour codes: Brown 

  -Phase, 

Live 

    Blue 

 -Neutral, 

Return 

    Green/ 

Yellow 

-Earth 

 

LIMITED WARRANTY 
 

Selecon New Zealand Ltd. (“Selecon”) warrants all Selecon theatrical fixtures against defects in materials or workmanship.  The term of this warranty 
is three years; from the date of delivery.  
Entertainment, Theatre relates to the typical conditions found in a theatre performance venue viz: 4 – 6 hrs per day, six days per week. 

 

 
Full warranty details are specified on the complete Operation Manual that is available as a 
.PDF from the product Specification section here: 

www.seleconlight.com/rama175fresnel

  

 

Manufacturer 

Selecon New Zealand, 19-21 Kawana Street, Northcote, Auckland 0627, New Zealand  

Ph: + 64 9 481 0100, Fax: + 64 9 481 0101 

www.seleconlight.com, E-mail: [email protected]

 

 