READ MODE:
To read Set 1 / set 2 delay time in ON delay or Interval mode
UPPER
DISPLAY
LOWER
DISPLAY
DESCRIPTION / COMMENTS
KEY
PRESS
(momentary)
SET key
SET key
lower display shows delay time of set 1
lower display shows delay time of set 2
SET key
SET key
SET key
SET key
lower display shows set 1 startup time
SET key
lower display shows set 1 on time
lower display shows
on time
set 2
SET key
lower display shows set 1 off time
lower display shows
off time
set 2
lower display shows
2 startup time
set
To read Startup time & Set 1 / Set 2 ON/ OFF time in CYCLIC mode
NOTE:
1)After selecting
in ON/ OFF delay mode &
in CYCLIC
mode press ENT key for 3sec. The timer will come out of programming &
will start functioning as per the settings.
2)If start up time =
then no start up delay (It is applicable for cyclic
ON first & cyclic OFF first modes.)
SET VALUES PROGRAMMING:
To enter set value programming
: Press SET key continuously for 3 sec.
To change value (timing)
: For 4 digits, four
keys are provided. The digit
above key increments by one for each momentary press of key. The
appropriate value can be selected accordingly by using keys. After selecting
appropriate time value press
ENT
key continuously for 3 sec to go to next step
of programming.
NOTE:
1. Set 2 has to be always less than Set 1 in ON & OFF delay mode. If set 2 value
is greater than Set 1, the Set 2 relay does not operate.
2. In down counting mode, relay 2 operates when time elapsed = set 2.
To exit set value programming
: Press MODE key continuously for 3 sec.
ENT Key
ENT Key
ENT Key
ENT Key
ENT Key
ENT Key
SET Key
Set 1 startup time
Set 2 startup time
Set 1 on time
Set 2 on time
Set 1 off time
Set 2 off time
Set point programming for CYCLIC mode
SET Key
Set 1 delay time
Set 2 delay time
UPPER
DISPLAY
LOWER
DISPLAY
COMMENTS
KEY PRESS
FOR 3 Sec.
Set point Programming for ON/ OFF Delay mode
Batch total is incremented by one after
each one cycle completed.
Press Third
Key from left
momentarily
i.e, key next to
SET key
Press ENT
for 3
Sec
Key
is selected as
or
by
momentarily pressing MODE key.
If ENT key is pressed for 3 Sec.
at
batch total is reset.
At
Batch total will not reset.
NOTE:
On continuous press of ‘MODE KEY’ after selecting ‘YES’ or ‘NO’,
it quits batch reset without altering batch total.
CONFIGURATION MODE:
Short terminal nos. 13 & 14
NOTE:
1) To enter or exit configuration mode, press MODE key for 3 Sec.
2) To go to next parameter programming, press ENT key for 3 Sec.
3) In programming mode the lower display blinks continuously.
KEY PRESS
FOR 3 Sec
(To select parameter press MODE key
momentarily)
DESCRIPTION/ COMMENTS
UPPER
DISPLAY
LOWER
DISPLAY
Select Power On Reset as
a)
b)
. If
timer
resets
on
: timer functions as a battery
backup timer.
:
power interruption.
If
I f
mode is selected then
will appear at the end.
Select reset as (a)
b)
All parameters set to default.
are
time = 0
They
Set 1 Start time, on time, off
Set 2 Start time, on time, off time = 0,
Batch total = 0, No. of Pulses = 0,
Mode = complex, Range = 99.99 Sec,
Delay mode = ON delay,
POR = No, Direction = Down,
Front panel reset = Yes,
Start input = Gate.
Timer will function as per
previous setting.
NOTE:
The below parameters will not appear in
mode.
In simple mode
these are factory sets as follows: a) Count direction: down, b) Front panel reset:
yes, c) Start input: gate & d) No of cycle pulses: 0 (continuous).
Select start input= (a)
(b)
When start (Gate) is high
(contact closed) the relay state does
not change but the time counting stops
(hold). On release of contact, time
counting starts from the last time count.
Timing starts on application of
external signal (open to close)
The function of this parameters is
same as explained earlier.
NOTE:
After selecting
press ENT key for 3 Sec. The timer will
come out from configuration programming and will start functioning as per
the configuration settings. Remove link between terminal nos. 13 & 14.
ENT Key
ENT Key
ENT Key
ENT Key
ENT Key
Select count direction as
(a)
(b)
ENT Key
Select Front Panel Reset as
(a)
(b)
Reset by front key enable
Reset by front key disable
ENT Key
Select: a)
for all functions.
b)
for limitted functions.
MODE Key
Select delay type as
(a)
(On delay)
(b)
(
Interval)
(c)
(
Cyclic with ON time first)
(d)
(Cyclic with OFF time first)
ENT Key
Time ranges s
a) 99.99 Sec. b) 999.9
) 9999 Sec. d) 99.59 min : sec.
e) 999.9 min f) 9999 min
g) 999.9 hr. h) 9999 hr.
electable as
Sec.
c
ENT Key
Select
:
This will appear if cyclic
mode is selected in operating mode. Set
no. of cyclic operations for relay one by
using keys momentary.
If
is selected then timer will operate
continuously in cyclic mode.
Document name: Operating / 0410/XT242/standard/ version4 OP007-V4(page 2 of 2)