7 TECHNICAL SPECIFICATIONS
QUASAR 320 MSE
QUASAR 400 MSE
QUASAR 500 MSE
Power supply voltage U1 (50/60Hz)
3x400V±15%
3x400V±15%
3x400V±15%
Zmax (@PCC)
*
- - -
Slow blow line fuse
25A
30A
40A
Communication bus
DIGITAL
DIGITAL
DIGITAL
Maximum input power (kVA)
16.2kVA
22.0kVA
29.7kVA
Maximum input power (kW)
10.9kW
16.2kW
22.2kW
Power factor PF
0.68
0.74
0.74
Efficiency (
μ
) 88%
89%
90%
Cos
ϕ
0.99
0.99
0.99
Max. input current I1max
23.2A
31.5A
42.1A
Effective current I1eff
16.5A
22.3A
29.7A
MMA duty factor (40°C)
(x=50%)
300A
400A
500A
(x=60%)
290A
360A
470A
(x=100%)
250A
340A
420A
MMA duty factor (25°C)
(x=80%)
300A
400A
500A
(x=100%)
290A
360A
470A
MIG/MAG duty factor (40°C)
(x=50%)
320A
400A
500A
(x=60%)
310A
360A
470A
(x=100%)
260A
340A
420A
MIG/MAG duty factor (25°C)
(x=80%)
/
400A
500A
(x=90%)
320A
/
/
(x=100%)
310A
360A
470A
Adjustment range I2
3÷320A
3÷400A
3÷500A
MMA open circuit voltage Uo
61Vdc
61Vdc
61Vdc
MIG/MAG open circuit voltage Uo
61Vdc
61Vdc
61Vdc
IP Protection rating
IP23S
IP23S
IP23S
Insulation class
H
H
H
Dimensions (lxdxh)
620x240x460mm
620x240x460mm
620x240x460mm
Weight
20.2kg.
22.5kg.
27.3kg.
Manufacturing Standards
EN 60974-1/EN 60974-10 EN 60974-1/EN 60974-10 EN 60974-1/EN 60974-10
Power supply cable
4x2.5mm2
4x4mm2
4x6mm2
Length of power supply cable
5m
5m
5m
QUASAR 320 MSE
*
This equipment complies with EN/IEC 61000-3-11.
*
This equipment does not comply with EN/IEC 61000-3-12. If it is connected to a public low voltage system, it is the responsibility of the
installer or user of the equipment to ensure, by consultation with the distribution network operator if necessary, that the equipment may be
connected. (Consult the “Electromagnetic fields & interferences” - " EMC equipment classification in accordance with EN/IEC 60974-10" section).
QUASAR 400-500 MSE
*
This equipment complies with EN/IEC 61000-3-11 if the maximum permissible mains impedance at the interface point to the public grid
(point of common coupling, PCC) is smaller than or equal to the Zmax stated value. If it is connected to a public low voltage system, it is
the responsibility of the installer or user of the equipment to ensure, by consultation with the distribution network operator if necessary, that the
equipment may be connected.
*
This equipment does not comply with EN/IEC 61000-3-12. If it is connected to a public low voltage system, it is the responsibility of the
installer or user of the equipment to ensure, by consultation with the distribution network operator if necessary, that the equipment may be
connected. (Consult the “Electromagnetic fields & interferences” - " EMC equipment classification in accordance with EN/IEC 60974-10" section).