7
7.00 Error search
Error
Possible cause
Error correction
•
The
appliance
will not
start
•
No network connection
•
Thermostat switched off
•
Thermostat not switched on
•
Starting device on compressor faulty
•
Fault in compressor (fault between
windings)
•
Create network
connection
•
Switch on thermostat
•
Change thermostat*
•
Change starting device*
(relay and condenser)
•
Change compressor*
•
Appliance
starts, but
does not
cool
•
Thermostat faulty
•
Condenser dirty
•
Condenser ventilator not working
•
Leakage in cooling system
•
Compressor faulty
•
Change thermostat*
•
Clean condenser
•
Change ventilator
•
Remove leak, evacuate
and fill with cooling
agent
2
(R134a)
•
Change compressor
2
•
Appliance
will not
switch off
•
Thermostat faulty
•
Leakage in cooling system
•
Change thermostat*
•
Remove leak, evacuate
and fill with cooling
agent
2
(R134a)
If the error cannot be corrected, please notify the appropriate service.
* This work may only be carried out be a trained electrician!
*This work may only be carried out by a trained cooling technician