Sel 3355-2 Скачать руководство пользователя страница 11

Schweitzer Engineering Laboratories, Inc.

SEL-3355-2 Data Sheet

11

Table 1

System Power Consumption

Power Consumption (Watts)

a

Component

Minimum

Typical

Maximum

Base System
(E3-1505L CPU, 1 PSU, 4GB RAM, 1 SATA Drive):

25 W

35 W

50 W

Additional Consumption From Optional Components

E3-1505M CPU:

+2 W

+5 W

+13 W

2nd Power Supply:

+10 W

+10 W

+13 W

8–64 GB RAM Configuration:

+2 W

+2 W

+3 W

Additional SATA Drives, Each:

+1 W

+2 W

+3 W

SEL-3390E4 Ethernet Card, Each:

+6 W

+8 W

+10 W

SEL-3390S8 Serial or SEL-3390T Expansion Card, Each:

+4 W

+5 W

+7 W

Chipset Heater

b

cold startup (<5°C [41°F]):

continuous operation (0°C [32°F]):

continuous operation (–40°C [–40°F]):

N/A

0 W

0 W

N/A

+5 W

+20 W

+90 W

+10 W

+40 W

a

Minimum: 0% load on all components; minimum power consumption started and idle.
Typical: 25–50% load on all components; good indication of most application loads.
Maximum: 100% load on all components; generally cannot be reached in normal applications.

b

Chipset heaters operate at low temperatures to keep the CPU and PCH within specified operating limits.

Table 2

Peripheral Connection Rated Current Output

Connection

Current Limit

DVI-D

0.2 A, +5 Vdc, 1 W total for both

DisplayPort

0.6 A, +3.3 Vdc, 2 W

COM 1 and COM 2

0.5 A, +5 Vdc, 2.5 W each

USB Ports

2 A, +5 Vdc, 10 W each, 25 W all ports combined

Содержание 3355-2

Страница 1: ...he need for external inverters and enhance system reliability availability and serviceability You can install software from SEL and third party software ven dors to customize the SEL 3355 2 for your s...

Страница 2: ...The SEL 3355 2 supports as many as four standard PCIe form factor expansion cards and one 32 bit PCI card enabling you to customize the system I O to meet your application needs Choose from a selectio...

Страница 3: ...ea net works LANs for control data or engineering access Time The SEL 3390S8 serial expansion card accepts IRIG B time code input for precise time input and distribution to connected devices EIA 232 E...

Страница 4: ...re 4 SEL 3355 2 as Remote Read Only Domain Controller Performing Central Authentication Using LDAP Disturbance Recording System for PRC 002 2 Figure 5 Reliable Hardware for Running Your Disturbance Re...

Страница 5: ...Ds for your custom application i USB Ports Two easily accessible ports to connect USB 3 1 peripherals o SATA Drive Bay Removable cover plate enables easy access to SATA drives from the front panel i y...

Страница 6: ...SEL 3355 2 Data Sheet Schweitzer Engineering Laboratories Inc 6 Product Dimensions Figure 9 SEL 3355 2 Dimensions for Rack and Panel Mount Models...

Страница 7: ...Hz base 2 8 GHz turbo Cache 1 MB L2 8 MB L3 Intel Xeon E3 1505M Quad Core Speed 2 8 GHz base 3 7 GHz turbo Cache 1 MB L2 8 MB L3 RAM 4 64 GB DDR4 ECC PC4 17000 2133 MHz Chipset Intel CM236 Chipset Exp...

Страница 8: ...SEL 3390S8 Expansion Cards As many as 24 additional EIA 232 422 485 ports RJ45 connectors 300 to 921600 bps Note See the SEL 3390S8 instruction manual for additional information Meets EIA TIA 562 Spec...

Страница 9: ...min Size 12 18 AWG Tightening Torque Minimum 0 6 Nm 5 in lb Maximum 0 8 Nm 7 in lb Crimp Ferrule Recommended Mounting Ear Tightening Torque Minimum 0 18 Nm 1 6 in lb Maximum 0 25 Nm 2 2 in lb Groundi...

Страница 10: ...14 2009 Severity Level 5 cycles 1 C per minute ramp 40 to 60 C E3 1505M CPU 40 to 75 C E3 1505L CPU Cold Operational IEC 60068 2 1 2007 Severity Level 16 hours at 40 C Cold Storage IEC 60068 2 1 2007...

Страница 11: ...pset Heaterb cold startup 5 C 41 F continuous operation 0 C 32 F continuous operation 40 C 40 F N A 0 W 0 W N A 5 W 20 W 90 W 10 W 40 W a Minimum 0 load on all components minimum power consumption sta...

Страница 12: ...d international copyright and patent laws in its products including without lim itation software firmware and documentation The information in this document is provided for informational use only and...

Отзывы: