38
-
Data reading settings
This section explains how to change various sheet-reading settings.
All settings can also be made using computer commands.
■
Setting column
Set the column. The number of columns is different depending on the reading sensor.
1.
Press
the
MENU
switch to enter the menu mode.
2.
Use
the
UP
and
DOWN
switches to select the following parameters,
and press the
FEED/ENTER
switch.
3.
Use
the
UP
and
DOWN
switches to select [Setting of Column] setting,
and press the
FEED/ENTER
switch.
(“
*
” mark
fl
ashes in the
fi
rst column of the
fi
rst line on the LCD.)
4.
Use
the
UP
and
DOWN
switches to set the value.
5.
Press
the
FEED/ENTER
switch to save the setting value into memory.
(The
fl
ashing “
*
” mark disappears from the LCD.)
6.
Keep pressing the
CLEAR/EXIT
switch until it returns to normal mode,
or press the
MENU
switch to return to normal mode.
Column setting values
1 - maximum columns
Sensor pitch
Setting range
Default value
1/6 inch
1-48 columns
48 columns
0.2 inch
1-40 columns
40 columns
0.25 inch
1-33 columns
33 columns
0.3 inch
1-27 columns
27 columns
Note)
It is necessary to set the number of columns with each operation mode.
Data reading settings
■
Setting column
SR-3565(E).indd 38
SR-3565(E).indd 38
2007-8-16 10:19:25
2007-8-16 10:19:25