![Sekonic SPL-450 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/sekonic/spl-450/spl-450_instruction-manual_1236351016.webp)
8)
Setting the dip switch
Two dip switches are provided on the rear panel. Set them
appropriately before turning on the power switch.
The SWI determines the communication method of the RS—
232
C
interface. The SW2 determines the default value of the character font. The
upper side is " ON", the lower side is "OFF" , and the left side is No. 1 . The
setting details are as shown below.
At shipping
Switch No.
Item
1-3
Baud rate setting
ON
OFF
See below
from factor
9, 600 baud
4
5
6
7
8
9
10
Baud rate
150
300
600
1200
2400
4800
Stop bit
Parity
Buffer size
Paper size
Unused
No.l
ON
OFF
ON
OFF
ON
OFF
ON
2
Yes
Even
5K bytes
ANSI(US)
No.3
ON
ON
ON
ON
OFF
OFF
OFF
1
No
Odd
1K byte
ISO(MET)
A3/B
1
No
Odd
1K byte
ISO
A3/B
No.2
ON
ON
OFF
OFF
ON
ON
OFF
9600