Paragraph 3 – Dosage Proportional to the Potential Redox Measurement (O.R.P.)
Programming Operation
Probe Calib.
On
O.F.Alarm
0m
Alarm Band
Prop. Band
Setpoint Type
High
Setpoint
560 mV
50 mV
200 mV
+
-
Pump Funtions
Configuration
Pump Functions
Redox Measure
PROG
-
-
+
-
+
-
+
-
+
-
+
-
+
-
-
-
-
-
The pump measures and controls the pH of a solution, programming in
sequence: set-point, set-point type, proportional band and alarm band
Set-point type: maximum
0
mV
s/m
max
flow-rate
Alarm Band
Alarm Band
Proportional
Band
se
t-
p
o
in
t
Ala
rm
O
n
Al
ar
m
O
n
Pump Off
Pu
m
p
O
n
Set-point type: minimum
0
mV
s/m
max
flow-rate
Alarm Band
Alarm Band
Proportional
Band
se
t-
p
o
in
t
Ala
rm
O
n
Al
ar
m
O
n
Pump Off
Pu
m
p O
n
It is also possible to programme:
-
the O.F.A. (Over Feed Alarm) time in minutes, or rather a time beyond
which an alarm signal is triggered if the pH value does not reach the set-
point.
-
The measurement resolution (1 or 2 decimal points)
-
Deactivation/activation of the calibration procedure
The maximum frequency can be modified during operation, by pressing
the
keys at the same time to increase the flow, or the
keys to decrease it.
Display during Operation
Display during Setting (MODE key)
High
F
F
F
560mV
Lev Stop P100%
•
Setpoint type;
High/Low
Alarms and statuses
•
Cal = calibration not
completed
•
Lev = Level alarm
•
Flw = Flow alarm
•
Alm = Measurement
outside alarm band
•
OFA = O.F.A. alarm
Flow sensor status
Potential Redox.
measurement value
Pump status
•
Empty = pump in start
•
Stop = pump stationary
•
Paus = pump in pause
Current dosage value
(depends on the selected unit
of measurement)
•
Percentage, Frequency,
l/h, Gph, ml/m
SP 560mV
450mV P100%
Displays in sequence
•
SP = Setpoint value
•
BP = Proportional band value
•
BA = Alarm band value
•
OFA = O.F.A. value
Measurement value
d ll
i
Maximum set dosage value
(depends on the selected unit of measurement)
•
Percentage, Frequency, l/h, Gph, ml/m
Paragraph 4 – Setting the Maximum Flow
Programming Operation
-
-
-
Pump Functions
Max flow rate
Max flow rate
Max flow rate
P100%
P100%
F320s/m
PROG
-
+
-
+
-
This makes it possible to set the maximum flow offered by
the pump, and the programmed mode (% or frequency) is
used as the standard unit of measurement when displaying
the flow. Changes can be made by pressing the
key,
then using the
keys to set the new value. Press
to confirm and return to the main menu
EM00136063 rev.