Calibration Procedure
SEKO Modular
Weighing System
Rinstum-R320
/323
Indicators.
Firmware
K356 v4.16
(Last revision
25 May
,2017
)
General comment:
Your
SEKO
Weighing System
can provide 99
.9
% or better accuracy and repeatability for most of
your
onboard weighing activities.
2
0
Calibration
CALIBRATION
The Calibration process is performed in three st
ep
s:
The first step establishes ZERO - the unloaded
forks
. We are actually weighing the empty forks
to
establish the ZERO (0) weight display
.
The second st
ep
records a known weight, called the
SPAN
weight.
All subsequent weights are calculated using the
ZERO
and
SPAN
as reference points upon a linear
vector.
Secure a known weight test load
. We recommend a weight of at least half of the maximum machine
safe lifting
capacity or
use
the maximum weight
of
your normal operation. Heavier is better than lighter.
Preliminary Tasks:
Activate Calibration Mode:
Simultaneously hold down the small
Power Key
and
"f/
OK
"
f
or two to four
seconds to
enter Set Up/Calibrate Mode and release the buttons when the display shows
FULL
SETUP
.
The indicator will display in automatic sequential order:
FULL
,
SETUP
, the
firmware I.D.
, and
bUiLD
(
BUILD
)
The unit is now ready to calibrate
ZERO
.
Содержание RINSTRUM K356