General Features

U

ser-friendly

 system available with built-in

 

troubleshooting diagnostics and our 24-7 

technical support line. 

307-321-4505

RS232 Printer accessory available providing

Technical Features

Input Power - Voltage: 

1

8

Vd

c

Input Power - Current/Amps: 

Maximum: 500mA

 

Inpu

t

Power - Current/Amps: 

Nominal: 

15

0mA

Excitation Voltage: 5Vdc 
Operating Temperature: 

14F to 104F (10C to 40C)

 

Control Panel Key Functions:

               

Power

/Units

, ZERO, Tare, 

Select

, Print, Function

Serial Port: 

Full Duplex RS-232 format

DisplayTechnology:

 6 digit LCD 3/4" heigh

t

Housing Material: 

Grey ABS

Weight: 1 lb. 6oz.

Shipping Weight: 

2 lb. 4oz.

 

Receipt Printer
Remote Switch for Accumulator Function

 

12Vdc Battery Line Conditioner
Voltage-Converter for  24Volt to 48Volt systems)

SEKO

 FORKLIFT SCALE

Accurate and Affordable Industrial Truck Scales

 

RINSTRUM 

Model 

R320/323

 - 

K356 

-

 

v

4.16

DIGITAL SCALE INDICATOR

Precision

 Static Weighing Lift Truck Scale.

 

Revised 

25

 June

,

 2017

 

System Technical Specifications

The 

SEKO

 Forklift Scale

 

Modular Load Cell

 weighing system determines the load weight by 

sensing the 

weight on the 

forks.

This signal is transmitted to the In-Cab 

Indicator

, which displays the weight on the forks. 

System is designed to work dependably and 

accurately in the harshest environments, 

Accumulation feature allows operators to either 

count up for total or display single load weight. 

Accurate and requires 

less than an hour

 

to

 install

 

and calibrate

weight, 

date, time and 

total

 weight. 

Two Setpoints with Isolated 300mA 50V Outputs

 

Internal Clock/Calendar

Options and Accessories:

1

Specification

Содержание RINSTRUM K356

Страница 1: ...itioner Voltage Converter for 24Volt to 48Volt systems SEKO FORKLIFT SCALE Accurate and Affordable Industrial Truck Scales RINSTRUM Model R320 323 K356 v4 16 DIGITAL SCALE INDICATOR Precision Static Weighing Lift Truck Scale Revised 25 June 2017 System Technical Specifications The SEKO Forklift Scale Modular Load Cell weighing system determines the load weight by sensing the weight on the forks Th...

Страница 2: ...Side View Front View Side View with Boot Rear View Rinstrum R320 Scale Indicator Face View Rinstrum R320 Scale Indicator Rear View Installation 2 ...

Страница 3: ...8Vdc from Truck Electrical Power may be attached via external plug or hardwired to internal Euro connector Connect power via Key Switch or directly to Battery Power Recommended in line fuse for truck electrical protection 2 0A Minimum For 24 36 48Vdc truck electrical systems contact Sales for Power Converter recommendations Installation 3 ...

Страница 4: ...GND From Alarm Accessory OUT 1 Jumper Install jumper provided in Alarm Kit from PWR to COM Connect Alarm Cable RED wire to OUT 1 Connect Alarm Cable BLACK Wire to GND Check to assure spring clips grip wire not insulation Power SetUp DTR Connection Optional Normally Not Connected 12 9 9 9 12 12 Standard Rinstrum Rear Panel Wiring Options Alt Brown Alt Grey Yellow or Clear Yellow or Clear Alt Brown ...

Страница 5: ...lay the weight of the load Liquid dangling and hanging loads can be difficult to weigh because the shifting load produces unstable inertial and gravitational stresses on the lifting mechanics Try to operate the truck to avoid sloshing swinging or bouncing of the load when lifting to weigh The Rinstrum Indicator can be set up for Live Weight weighing of unstable loads such as live animals See Secti...

Страница 6: ...3 and NTEP certified S beam type load cells producing signals with 0 03 error The SEKO weigh module low friction mechanical design allows better than 0 1 displayed weight error in practice Mast tilt can cause weighing errors due to the altered gravitational vector producing strain on the scale load cells In normal truck operation this effect is small and generally not noticed However when 0 1 accu...

Страница 7: ...fy this issue the instrument must be turned off When the instrument is turned back on the Passcode counter is reset to zero allowing the user to enter the correct Passcode SAFE PC Safe Passcode for Operator access allows partial access to Digital Setup ie only non calibration trade critical settings can be changed For the Safe Passcode SAFE PC to have any effect the FULL PC Full Passcode must also...

Страница 8: ... Voltage polarity at the Indicator Connection Note Use a Voltmeter if possible to verify that the proper Voltage and polarity is present at all test points 2 If the wiring to the scale indicator is equipped with a fuse check the fuse Note The standard LTWS 1 hydraulic weighing systems normally consume less than 0 200 Amperes 200 milli Amp The purpose of a in line fuse is to protect the truck elect...

Страница 9: ... problem is intermittent Voltage readings and Indicator Display should show no aberrations flicker etc If movement of the Indicator affects the Primary Power test each power connection If Primary Power is delivered via a plug at the side of the Indicator check that the plug is the correct size to fit the barrel and also the center pin Install the correct size plug if this connection is physically ...

Страница 10: ...ecimals CAP 5000 RES 1 DUAL 60000 UNITS lb HI RES OFF CABLE 4 Navigation Press ZERO Button to select major setting Group Press TARE Button to select Setting Press SELECT Button to acivate selected Setting Use SELECT and PRINT Buttons to select and adjust Settings Use f OK Button to save the selected Setting f OK Button saving is temporary You MUST use the ZERO Button to go to END then press the TA...

Страница 11: ...icator to turn the Indicator ON The Indicator should turn on automatically The Indicator will flash firmware codes and then display a static Weight If the forks are on the ground this number may be a negative weight Activate Setup and Calibration Mode FULL SETUP Codes bUiLD Hold down the small Power and f OK buttons together for about three 3 Seconds to enter SetUp Calibrate Mode The indicator wil...

Страница 12: ... the Scale The display may show 005000 or Press SELECT another weight Set the Maximum Scale Weighing Capacity The Capacity should be set to one of the following amounts The label safe rated lift capacity of the machine Slightly above the maximum weight to be lifted in your application Press SELECT to select digit and PRINT to change the value of the selected digit The selected digit will flash SEK...

Страница 13: ...m increments is 3000 CAP divided by RES should always be 3000 or less Press f OK to store the Display Resolution setting The Display will show rES The display may show 000000 without any Unit designation to select desired UNITS designation Press PRINT desired Options none g kg Lb t Press f OK to store the UNitS setting The Display will show UNITS Set High Resolution Option Press T Tare to select H...

Страница 14: ...Transducer Cable Type If 6 Press PRINT and the display will show 4 Standard hydraulic forklift sensor is 4 wire cable Set Indicator Use Type Industrial NTEP OIML Press T Tare Display to select USE Press SELECT Display shows iNdUSt NtEP or OimL Default iNdUSt This is the correct setting Press f OK to store the USE setting The Display will show USE Press T Tare to select FiLTEr Set Filter None 2 5 1...

Страница 15: ...ss PRINT shows 0 5 1 0 Press f OK to store the 0 5 1 0 setting The Display will show mOt iON Set Initial Zero OFF ON to select iNit Z Press T Tare Press SELECT key Display will show OFF If ON press PRINT until Display shows OFF Press f OK to store the OFF setting The Display will show iNit Z Set Zero Tracking OFF FASt mEd SLOw Press T Tare Display will show Z trAC Display will show OFF If ON press...

Страница 16: ...Set Zero Tracking Band Z bANd Zero Band Press T Tare Press SELECT and the display will show 000000 and PRINT If other value adjust with SELECT until Display shows 000000 to store the setting The Display will The display will show r ENTrY Display will show OFF If ON press PRINT until Display shows OFF Press SELECT Display will show OFF If ON press PRINT until Display shows OFF Press f OK show Z bAN...

Страница 17: ...ss 0 ZERO The Display will show LivE Press 0 ZERO The Display will show CLOC Press 0 ZERO The Display will show SPEC Press 0 ZERO Please contact Tech Support for the following setting instructions 307 321 4505 24 7 TEST Diagnostic Press 0 ZERO The display will show tESt TEST is a diagnostic mode and has no operator settings adjusted mV from the Transducer Analog Converter This number format is 0 0...

Страница 18: ...Exit Programming Mode The display will show END Press 0 ZERO Save Settings Exit and Re Start Weighing Mode To Save and Exit Display will Press T Tare show SAviNG At this point Setup is complete Please proceed to Calibration Procedure Factory Reset NOT ADVISED ...

Страница 19: ...19 ...

Страница 20: ...ecords a known weight called the SPAN weight All subsequent weights are calculated using the ZERO and SPAN as reference points upon a linear vector Secure a known weight test load We recommend a weight of at least half of the maximum machine safe lifting capacity or use the maximum weight of your normal operation Heavier is better than lighter Preliminary Tasks Activate Calibration Mode Simultaneo...

Страница 21: ...CT key and the display will show some flashing number Press T Tare to select ZErO ZERO to store the ZErO Lift the empty forks to the weighing point and press f OK ZERO setting The Display will show Z in P momentarily then display 0 lb 21 Cali brat ion ...

Страница 22: ...r with the PRINT key Lift the test weight and stop at the height where you will normally weigh your loads Press f OK to store the SPAN SPAN setting The Display will show S in P momentarily then display a flashing weight Cali brat ion 22 to SAVE and Exit Press T Tare The display will show SAvinG and enter normal Weighing Mode Press to store the CLr L N setting The Display will show a flashing 0 lb ...

Страница 23: ... ZERO button to go to CAL Press TARE button two times to go to SPAN Press SELECT button two 2 times to enter new SPAN calibration weight The display will show the previous SPAN calibration weight Use SELECT and PRINT buttons to enter an adjusted SPAN calibration weight If the scale reads high then decrease the SPAN calibration weight by approximately 1 2 50 of the error Lift the Test Weight and Pr...

Страница 24: ...AL Press TARE button two times to go to SPAN Press SELECT button two 2 times to enter new SPAN calibration weight The display will show the previous SPAN calibration weight Use SELECT and PRINT buttons to enter an adjusted SPAN calibration weight If the scale reads high then decrease the SPAN calibration weight by approximately 1 2 50 of the error Lift the Test Weight and Press f OK button to stor...