EM00136299
rev. 1.0 IT
15
Alarms
Dislay
Cause
Remedy
Alarm LED on
“Lev” icon flashing
End level alarm, without pump
operation interruption.
Restore the liquid level.
Alarm LED on
“Lev” and “Stop” icons flashing
End level alarm, with pump
operation interruption.
Restore the liquid level.
“Mem” icon flashing
The pump receives one or more
impulses during the dosage with the
memory function set to Off
Press the
key.
“Mem” icon flashing
The pump receives one or more
impulses during the dosage with the
memory function set to On
When the pump finishes receiving
external impulses, it returns the
memorized strokes
Alarm LED on
“Flw” icon flashing
Flow alarm activated, the pump has
not received from the flow sensor
the programmed number of signals.
Press the
key.
Parameter Error
Internal CPU communication error.
Press the
key to restore the
default parameters.