EM00136225
rev.1.0 EN
5
KOMPACT AMC
–
Control Panel
CONSTANT MODE (switch in position C)
The pump dispenses the percentage selected manually with a potentiometer.
Steady green LED switches off with every stroke that the pump runs.
Flashing Green led with the potentiometer to 0.
PROPORTIONAL MODE 4:1 (switch in position P)
After four received external pulses (pulse emission meter) and with the potentiometer at 100% of its regulation, it
runs a stroke.
The potentiometer permits an increase in the number of received external pulses, after which the pump runs a
stroke.
Below are some examples of operation:
Potentiometer [%]
1 stroke / Pulses
100
4
50
8
10
40
Steady orange LED switches off with every stroke that the pump runs.
Flashing orange LED with the potentiometer at 0.
calibratio
n
meter
Q
n
max pul/min available from
meter
[Q
n
x
pul/l]
max pump frequency
[4 pulse meter = 1 pulse
pump]
max ppm available
to max frequency
5
0.69
pul/l
l/pul
pul/l
l/pul
pul/l
l/pul
size
m
3
/h
4
1
100
1000
4
1
100
1000
4
1
100
1000
1/2"
1.5
100
25
25
6
521
130
3/4"
2.5
167
42
42
10
521
130
1"
3.5
233
58
58
15
521
130
1"1/4
5
333
83
83
21
521
130
1"1/2
10
667
167
160
42
500
130
2"
15
1,000
250
2.5
160
63
0.63
333
130
1.3
2"1/2
25
4.2
1.04
1.3
3"
40
6.7
1.67
1.3
4"
60
10.0
2.50
1.3
6"
150
2.5
0.63
0.13
ALARMS
Display
Cause
Interruption
Steady red LED
switches on.
End level alarm.
Restore liquid level.
LED for dosing indication
and level probe alarm
signal
Potentiometer for% flow rate
regulation
Содержание KOMPACT AMC