INSTANT FLEXIBLE DIGITAL THERMOMETER 10 SECONDES 

OWNER’S MANUAL 

Model : MT-4333 

 

Warning: 

 

Read instructions thoroughly before using digital thermometer. 

 

Choking Hazard:  Thermometer cap and battery may be fatal if swallowed.  Do 

not allow children to use this device without parental supervision. 

 

Do not use thermometer in ear.  Designed use is for oral, rectal, and armpit 

(axilla) readings only. 

 

Do not place thermometer battery near extreme heat as it may explode. 

 

Note: Use of the probe cover may result in a 0.1

℃ 

(0.2

) discrepancy from 

actual temperature. 

 

Remove battery from the device when not in operation for a long time. 

 

The use of temperature readings for self-diagnosis is dangerous.  Consult your 

doctor for the interpretation of results. Self-diagnosis may lead to the worsening of 

existing disease conditions. 

 

Do not attempt measurements when the thermometer is wet as inaccurate 

readings may result. 

 

Do not bite the thermometer. Doing so may lead to breakage and/or injury. 

 

Do not attempt to disassemble or repair the thermometer. Doing so may 

result in inaccurate readings. 

 

After each use, disinfect the thermometer especially in case the device is used 

by more than one person. 

 

Do not force the thermometer into the rectum. Stop insertion and abort the 

measurement when pain is present. Failure to do so may lead to injury. 

 

Do not use thermometer orally after being used rectally. 

 

For children who are two years old or younger, please do not use the devices 

orally. 

 

If the unit has been stored at temperatures over 5

40

(41

104

), 

leave it in 5

40

℃ 

(41

104

) ambient temperature for about 15 minutes 

before using it. 

 

 

PLEASE  READ  CAREFULLY  BEFORE  USING 

Thi  s digital thermometer provides a quick and highly accurate reading of an individual's 

body temperature. The digital thermometer  is intended to measure the human body’s 

temperature in regular mode orally, rectally or under the arm, and the device is reusable for 

clinical or home  

Содержание MT-4333

Страница 1: ...wet as inaccurate readings may result Do not bite the thermometer Doing so may lead to breakage and or injury Do not attempt to disassemble or repair the thermometer Doing so may result in inaccurate readings After each use disinfect the thermometer especially in case the device is used by more than one person Do not force the thermometer into the rectum Stop insertion and abort the measurement wh...

Страница 2: ...ronment and complies with the requirements of EN 60601 1 2 EMC IEC EN60601 1 Safety standards And the manufacturer is ISO 13485 certified CONTENTS 1 Thermometer 1 Owner s Manual 1 Storage Case PRODUCT ILLUSTRATION PRECAUTION The performance of the device may be degraded should one or more of the following occur Operation outside the manufacturer s stated temperature and humidity range Storage outs...

Страница 3: ...1060hPa Storage and transportation condition Temperature 20 55 4 131 Humidity 15 95 RH Atmospheric Pressure 700hPa 1060hPa Ingress Protection Rating IP27 Classification Type BF SWITCHABLE Temperature readings are available in the Celsius or Fahrenheit scale located in the upper right corner of LCD With the unit off press and hold the On Off Button for approximately 2 seconds to change the current ...

Страница 4: ...buzzes are Bi Bi Bi Bi Alarm beeps more rapidly when temperature reaches 37 8 100 or higher and the buzzes are Bi Bi Bi Bi Bi Bi Bi Bi Bi 4 To prolong battery life press the On Off Button to turn unit off after testing is complete If no action is taken the unit will automatically shut off after around10 minutes TROUBLESHOOTING Error message Problem Solution Temperature taken is lower than 32 0 C 9...

Страница 5: ...hly Finish by wiping with a soft dry cloth For disinfection 75 Ethanol or Isopropyl alcohol can be used Observe the following to prevent damage to the thermometer Do not use benzene thinner gasoline or other strong solvents to clean the thermometer Do not attempt to disinfect the sensing section tip of the thermometer by immersing in alcohol or in hot water water over 50 122 Do not use ultrasonic ...

Страница 6: ...The product is in compliance with the requirements of MDD 93 42 EEC 0197 is the identification number of notify body 0197 ...