background image

Operation

Key Functions

The 

,

 

 

and 

 

 keys are used to select

what to display, set backlight levels, calibrate speed, temperature
and clock speed and set/change constants and units of
display. New information is automatically saved to non-volatile
memory.

Backlight Intensity
Press 

 

the key 1/2 second to adjust the backlight level for

night viewing. Each time you press the 

 

key 1/2 second, the

level will get brighter 1, 2, 3, 4, OFF, 1, 2, ... etc. The blue
backlight ON/OFF control wire in cable #1 must be switched
to +12/24V for the backlights to work and offers external
backlight ON/OFF control. If ON/OFF control is not
required, connect the blue wire to +12/24VDC permanently.

Display Speed/Logs/Water Temperature
Press the 

, or 

 

key to select Speed, Logs or Water

Temperature display. Pressing the 

 

key again while

displaying speed will toggle the display between speed and

Содержание SW RP07

Страница 1: ...SW RP07 ...

Страница 2: ...er is presettable for two different start times from 1 to 99 minutes each It beeps off the minutes and last ten seconds before reaching zero After reaching zero the race timer continues to track elapsed time Speed can be displayed in Knots MPH and KM H with selectable display damping Temperature can be displayed in degrees Fahrenheit or Celsius Speed temperature and clock speed may all be calibrat...

Страница 3: ...starting the installation please read this entire section first Finger tighten the screws that mount the instrument bracket It is not necessary or recommended to use tools Drill a 2 1 8 55mm mounting hole where you desire to mount the instrument Figure 1 Connect the various wires from Cable 1 and Cable 2 as shown in Figures 2 and Figure 3 Carefully check all your wiring against figures 2 and 3 and...

Страница 4: ...r night viewing Each time you press the key 1 2 second the level will get brighter 1 2 3 4 OFF 1 2 etc The blue backlight ON OFF control wire in cable 1 must be switched to 12 24V for the backlights to work and offers external backlight ON OFF control If ON OFF control is not required connect the blue wire to 12 24VDC permanently Display Speed Logs Water Temperature Press the or key to select Spee...

Страница 5: ...e elapsed time since the instrument was turned on When the elapsed time exceeds 60 minutes the elapsed time clock displays hours and minutes in place of minutes and seconds and the semi colon flashes Resetting the Trip Log Elapsed Time Clock While viewing the Trip Log press and hold the key for 10 seconds till you hear a long beep to reset both the trip log and elapsed time clock to zero Display S...

Страница 6: ... adjusted according to the chosen units of measure for the speed Selecting Average Speed Damping Press and hold the and keys for ten seconds while viewing Average Speed until you hear a long beep Use the and keys to adjust the Speed Damping value to any number between 1 and 20 Press the key to save the new value to memory The factory default Speed Damping is set to 10 Calibrating Temperature To ca...

Страница 7: ... VWVLW xxxx N yyy y N CS Speed Knots km h VWVHW xx x N yyy y K CS CS Check Sum Notes and Warnings a During calibration or setting of alarm values pressing and holding down the or keys will cause the values to scroll faster the longer you hold down the keys Other Seiwa Products lIs possible to connect to SW RP07 to all the Seiwa multifunction chartplotters and use it for take the temperature and th...

Отзывы: