background image

Operation

Key Functions

The 

 

and 

  

keys are used to select what to display, set

backlight levels, turn alarms on/off, set alarms values, set/
change keel offset and display damping. New information is
automatically saved to non-volatile memory.

Turning Alarms ON/OFF
Press the

   

key 1/2 second to turn alarms ON. The alarm icon

will light. Press the 

 

key 1/2 second to turn the alarms and

alarm icon OFF.

Backlight Intensity

Содержание SW RP05

Страница 1: ...SW RP05 ...

Страница 2: ...ms built in and can display the depth in feet metres or fathoms A keel offset from 20 0 to 20 0 feet can be entered so the SW RP05 shows the depth below the surface below the keel or below the transducer Under 20 feet Meters or Fathoms the depth is displayed in tenths The SW RP05 outputs NMEA 0183 serial data as a standard SDDPT Depth below the transducer sentence If not required the NMEA 0183 dat...

Страница 3: ...display damping NMEA 0183 Out SDDPT Depth below transducer Installation Before starting the installation please read this entire section first Finger tighten the screws that mount the instrument bracket It is not necessary or recommended to use tools Drill a 2 1 8 55mm mounting hole where you desire to mount the instrument Figure 1 Connect the various wires from Cable 1 and Cable 2 as shown in Fig...

Страница 4: ...s on off set alarms values set change keel offset and display damping New information is automatically saved to non volatile memory Turning Alarms ON OFF Press the key 1 2 second to turn alarms ON The alarm icon will light Press the key 1 2 second to turn the alarms and alarm icon OFF Backlight Intensity ...

Страница 5: ...d keys to set the desired alarm value Press the key to save the deep depth alarm value to memory Setting Anchor Drag Alarm After anchoring set the shallow alarm a few feet more shallow than the actual displayed depth Similarly set the deep alarm a few feet deeper than the actual displayed depth Make allowances for local tidal changes to prevent false alarms Setting Keel Offset While viewing Depth ...

Страница 6: ...saved to memory A 5V signal 10 mA Max is output whenever an alarm condition exists and the alarms are enabled NMEA 0183 Sentence The SW RP05 outputs serial data of depth in NMEA 0183 format The sentence is output in the following format Depth SDDPT xxx x yyy y CS xxx x Depth in Metres yyy y Keel offset in Metres CS Check Sum Notes and Warnings a The displayed depth should be used as a guide and ca...