CAUTION

To ensure brightness and safety, carry out cleaning and inspection periodically.
If you find a problem, stop using he product and have it repaired by a specialist.

Never touch the lamp and its surroundings while it is on or just after it is turned off.
The lamp and its surroundings are very hot. An accidental touch might burn yourself.

Don’t use the product at a voltage other than the voltage indicated on the nameplate. The voltage variation
should be within ±6% of the rating. Otherwise a damage, fire or electric shock might result.

Don’t use the product at a frequency other than the local power supply frequency (50 or 60 Hz).
A wrong frequency might cause a fire.

The product should be installed by a qualified person.
Installation by an unqualified person is legally prohibited.

Because this product is painted non-metallic coating , please refer to the note below.
・Avoid friction ・No dry cleaning ・Do not mount in areas with flowing, non-conductive products

 

WARNING

When leading the power cable into the product, be sure to follow the technical standards for electrical equipment and
the guide for the explosion protection of factory electrical equipment. Inadequate cable connection or poor
waterproofing might cause an explosion, fire or electric shock.

In grounding work, follow the technical standards for electrical equipment and the guide for the explosion protection of
factory electrical equipment. Inadequate grounding might cause an explosion, fire or electric shock.

Don’t convert the product.
Conversion might cause fall of the product, an explosion, fire or electric shock.

The non-metallic coating is painted on the surface of the product and the non-metallic label is attached on the surface
of the product, electrostatic charge may cause an explosion hazard. Avoid any actions that cause the generation of
electrostatic charge, such as rubbing with a dry cloth on coating surface of the product.

Don’t cover the product with an inflammable material such as cloth or paper nor put anything in the product. Such a
material or thing might cause an explosion or fire.

For outdoor use, waterproof the screw connections and the entries of the terminal box to prevent rainwater
infiltration. For the stanchion type, waterproof the screw connections of the stand pole to prevent rainwater
infiltration. Inadequate waterproofing might cause a fire or electric shock.

Don’t open or loosen any part unless necessary. Confirm that the screws, bolts and the like are fastened tightly. A
loose part might cause an explosion, fall, fire or electric shock.

Prior to maintenance or inspection, be sure to turn off the power and wait at least ten minutes before opening the
enclosure. An explosion, fire or electric shock might result.

If you continue to use the product in an abnormal condition (smoke, odor, etc.), an explosion, fire or electric shock
might result. If you detect an abnormality, immediately turn off the power switch. Confirm that the abnormal condition
has been eliminated and have it repaired by a specialist.

The components once removed for cleaning or maintenance should be replaced properly according to the instruction
manual. An incorrectly placed component might cause an explosion or fall, resulting in an injury or property damage.

Содержание LZWA1404

Страница 1: ... there is explosive atmospheres The product should be of the flameproof type suitable for each hazardous area Use of an unsuitable product might cause an explosion or fire For electrical connection be sure to connect the wires in the terminal box securely using crimp type terminals etc and conduct insulation treatment An inadequate connection or inadequate insulation might cause a contact failure ...

Страница 2: ...might cause fall of the product an explosion fire or electric shock The non metallic coating is painted on the surface of the product and the non metallic label is attached on the surface of the product electrostatic charge may cause an explosion hazard Avoid any actions that cause the generation of electrostatic charge such as rubbing with a dry cloth on coating surface of the product Don t cover...

Страница 3: ...the mounting bracket on the mounting surface firmly 2 Cant the fitting to 90 3 Open the terminal box cover and connect the power wires white and black and grounding wire green inside the terminal box properly Connection method is that the reference to the following P 6 The internal earthing conductor should be mounted and secured at other wires to prevent the twisting 4 Secure the terminal box cov...

Страница 4: ...mounting bracket The product is mounted on a ceiling The lamp house is installed within an angle range from 0 to 70 degrees in the left and right directions For angle adjustment loosen the two hexagon socket head bolts on the retainer After adjustment be sure to tighten the hexagon socket head bolts 6 According to the left figure it should be grounded the external ground reliably The external eart...

Страница 5: ...d cables which are suitable for the operating temperature range referring to the following 25ºC Ta 45ºC Plug 25 ºC to 75ºC Cable gland 25 ºC to 75ºC Cables 25 ºC to 75ºC 25ºC Ta 55ºC Plug 25 ºC to 85ºC Cable gland 25 ºC to 85ºC Cables 25 ºC to 85ºC The accessory plug can be used up to ambient temperature 50 Confirm that the fitting is adequately grounded Prior to maintenance or inspection be sure ...

Страница 6: ...Fax 81 3 5833 8971 BANGKOK REP OFFICE 2 Jasmine City Building 17th Floor Sukhumvit Soi 23 Prasarn Mitr Sukhumvit Road Klongtoey Nue Wattana Bangkok 10110 Phone 66 0 2 204 5143 CHINA OFFICE No 8 Xuzhou Road Changshu Jiangsu 215500 China Phone 86 512 5284 9957 CONTACT SEIWA ELECTRIC MFG CO LTD For further information on the product contact our offices below let us know the model name indicated on th...

Страница 7: ...7 ...

Страница 8: ...8 ...

Отзывы: