background image

Thank you very much for purchasing our LED lighting fittings.
Please read this instruction manual to use the product properly.

1) Prior to installing the fitting, check if the product is as per your order.

2) Check for a loose or damaged part due to an accident in transit, etc. 

1) The electrical characteristic data is given below.

-  Installation work should be done properly by a qualified electrician in accordance with the related laws and the instruction manual.

-  For safety, Installation work should be done by at least two workers.

Lighting fitting for inside inspection

NB1:

NB2: The mounting brackets are optionally available. 

For further i for atio , see  Optio : Mou ti g Bracket.

NB:

NB1: Use M8 or larger bolts to mount it on the structure.

NB2:

LCTD1101

 81

-N

(5000K)

IP65

Please perform connection of power wires and insulating.
The colors of power wire are white and red. The color of earth
wire is black.

Vapor Tight Type LED Lighting Fittings

LCTD

After installing the product, be sure to hand this manual over to the user of the product. 

Model

100-242V AC

50 / 60Hz

Input

Current

Power

Consumption

IP

rating

Mount the lamp house with the attached mounting brackets
on the structure (tank inspection hole, etc.) firmly.

Fig.1

 81M -W

11E0001151A11

To be conserved

Instruction Manual

Option

(3000K)

Input Voltage

(Frequency)

0.16-0.07A

When the supplied cross-recessed pan head machine
screws are used, the recommended thickness of the
mounting bracket is 2 to 5 mm.

Mounting Bracket

-M

Prior to use

Performance

Prepare robust mounting brackets to be attached to the lamp
house (fitting) referring to the figure on the right (mounting
hole positions).

Attach and fix the mounting brackets at four places (90 °
pitch) or three places (120° pitch).

Among the 12 cross-recessed pan head machine screws
(M5x12, with plain and spring washers) on the lamp house,
remove as many ones as needed. After removal, attach the
mounting brackets to the lamp house using as many cross-
recessed pan head machine screws as needed.

15.0-15.5W

Names of the Components and Installation Method

Be sure to fix the mounting brackets and lamp house firmly
using the mounting screw holes, though the mounting
bracket height (distance from the tank inspection hole,

etc.) is not limited.

Fig.2

CABLE 

HVCT 1.25mm

2

×

3C

 

(2m) 

Mounting  bracket (option) 

(not supplied) 

Lamp house fittings  

2

×

6-M5 Mounting  screw

 

holes

 

Screw

 

hole depth:8 

12 cross-recessed pan head machine screw 
M5

×

12

 

with spring and plain washers(supplied) 

 

-   -

Содержание LCTD110181-N

Страница 1: ...with the attached mounting brackets on the structure tank inspection hole etc firmly Fig 1 81M W 11E0001151A11 To be conserved Instruction Manual Option 3000K Input Voltage Frequency 0 16 0 07A When the supplied cross recessed pan head machine screws are used the recommended thickness of the mounting bracket is 2 to 5 mm Mounting Bracket M Prior to use Performance Prepare robust mounting brackets ...

Страница 2: ...hen the product is in use never disassemble it 2 For disposal of the product follow the regulations and rules of your local government When reordering please let us know Drawing or drawing No for the delivered product Manufacturing lot number on the nameplate Fig 4 How to Use Maintenance In cleaning the fitting gently wipe with water or mild detergent Don t use thinner benzene or alkaline detergen...

Страница 3: ... glass to prevent the product from being affected by radiation heat In grounding work be sure to follow the technical standards for electrical equipment of your country Don t open the front glass The internal components such as the LED lamp become very hot Don t touch the LED lamp since a malfunction or lighting failure might occur For white LED lamps the luminescent color and brightness may vary ...

Страница 4: ...rical equipmentof your country Inadequate grounding might cause a fire or electric shock Be sure to follow the instructions Be sure to ground For electrical connections use crimp type terminals etc to secure the connections and conduct insulation treatment An inadequate connection or inadequate insulation might cause an imperfect contact leading to a fire or electric shock When leading the power c...

Страница 5: ...ada Joyo Kyoto Pref 610 0192 Japan Tokyo Branch SEIWA ELECTRIC MFG CO LTD Phone CAUTION A lighting fitting has a service life A product which has been used for eight to ten years may have degraded internal parts even if it looks normal For safety and energy saving we recommend you check and replace it The LED module design life is 60 000 hours different from the lighting fitting life when used at ...