background image

DCD02B2001SE 040429 281122

22

USER PARAMETERS SETTING

On the menu “User parameters“ it is possible to configure all freetime evo radio settings.

Below, there is the sequence to enter the view and/or edit mode of user parameters.

1.

From the normal operation screen,
keep the knob pressed for more than 10 seconds.

2.

The display shows the first user parameter.

3.

Turning the knob 

scrolls through the 16 available user parameters:

H_C  PAr 1.0 
AFr  PAr 2.0 

Entc  PAr 3.0 

 

LinF 

PAr 3.1   

 

LSUP 

PAr 3.2 

OFS1 PAr 4.0  
OFS2 PAr 5.0  
HYSt  PAr 6.0  
tPI     PAr 7.0    
 

bP 

PAr 7.1 

 

tInt  

PAr 7.2    

 

PCYC 

PAr 7.3  

 

PMIn 

PAr 7.4  

tMIn  PAr 8.0  
EOrM PAr 9.0  
dFLt  PAr 10.0

Name of the parameter

The icon shows that the user 

parameters menu is entered.

Number of the selected 

parameter.

x_C

PAr

1.0

x_C

PAr

1.0

Содержание freetime evo

Страница 1: ...Freetime Evo Radio U S E R M A N U A L Daily Weekly wireless programmable thermostat ...

Страница 2: ......

Страница 3: ...TROL OF A PELLET STOVE 7 INSERTING REPLACING THE BATTERIES 8 BATTERY LEVEL 8 KEYS AND KNOB FUNCTIONS 9 DISPLAY 10 DAILY WEEKLY PROGRAM SETTING 11 TIME CURRENT DAY REGULATION 11 HEATING COOLING SETTING 11 COMFORT TEMPERATURE SETTING 12 ECONOMY TEMPERATURE SETTING 12 DAILY TIME PROGRAM SETTING 13 WEEKLY TIME PROGRAM SETTING 14 TIME SCHEDULE SHARING WITH OTHER WIRELESS THERMOSTATS 15 MANUAL OPERATION...

Страница 4: ......

Страница 5: ...the remote sensor in areas which are not suitable for room temperature detection TECHNICAL FEATURES Power supply 2 x 1 5V alkaline Type AA Battery life 3 years Frequency 868 150 MHz Modulation GFSK Max transmitted RF power 1 mW Antenna type Internal Max distance from the receiver 300 m in open field or 50 m inside buildings it depends on building and environment Regulation field comfort 5 C 40 C e...

Страница 6: ...te probe can be connected to sense room temperature in case the programmable thermostat needs to be installed in a location not suitable for sensing room temperature Alternatively the remote probe can be configured to measure floor temperature a useful function in underfloor heating systems In case the installation requires the installation of a remote probe it is necessary to connect a probe with...

Страница 7: ...e display and in the receiver the relay of the relevant output should continuously turn on and off every 2 seconds the status is also indicated by the relevant Led If this happens the thermostat communicates correctly with the receiver When placing the thermostat in the desired room make sure that the two devices are still communicating properly If the thermostat is positioned too far away from th...

Страница 8: ... in the special containers for recycling Replace the batteries within a few seconds in order not to lose the set time BATTERY LEVEL The display always shows the battery life status with the symbol The battery life is full if all 3 indicators are on inside the battery symbol On the contrary the batteries are low and must be replaced if the display shows the symbol with only one bar left WARNING If ...

Страница 9: ...e function key Turn on off freetime evo Exit from Edit mode when on hourly program or user parameters settings Multi functions knob On normal operation By pushing the knob shows the time of the detected room temperature If the backlight is off by rotating the knob it activates the display backlight On Comfort Economy temperature setting when the keys or are pressed by rotating the knob it is possi...

Страница 10: ...tion in heating mode relay activated Activation in cooling mode relay activated 24h Room temperature regulation in Manual mode until 24 00 24h Room temperature regulation in permanent Manual mode The programmable thermostat is on User parameters setting or freetime evo shows a fault condition Programmable thermostat off Regulation interrupted Pause mode for less than 96 hours when the time is fini...

Страница 11: ...that the programmable thermostat is set to weekly program mode it asks to set the clock and the current day of the week see chapter Time current day regulation TIME CURRENT DAY REGULATION In order to set the clock of the programmable thermostats follow instructions below 1 Open the flap which gives access to the buttons 2 Push for at least 2 seconds the button the display shows Set CLO and the hou...

Страница 12: ...es access to the buttons 2 Push the button 3 Rotate the knob to adjust the regulation temperature Set point 4 Confirm the set value with or pushing the knob WARNING Normally in order to get a temperature decrease the Economy temperature must be set to a lower value than the Comfort temperature The arrow placed near the economy Set point temperature blinks indicating the edit mode This is the room ...

Страница 13: ... mode on the time histogram bar it is shown the segment on the lower strip Push to set the Off Mode OFF Antifrost NO segment is displayed on the time histogram bar At every push of the button or the clock moves on the next half hour Every segment shown on the time histogram represents half an hour Set the desired mode for the next half hours up to complete the entire day by repeatedly pressing or ...

Страница 14: ...o set the Off mode OFF Antifrost NO segment is displayed on the time histogram bar At every push of the button or or the clock moves on the next half hour Every segment shown on the time histogram represents half an hour Select the required mode for the next half hours until the entire day is completed by repeatedly pushing the button or or Once the daily program is completed proceed as follows Pu...

Страница 15: ...e programmed in the programmable thermostat This can be achieved using a multi channel receiver and associating the outputs driven by the themostats to the output driven by the programmable thermostat In this way a programmable thermostat and the thermostats associated with it will form a zone For example in a home it would be possible to create the living zone and the bedroom zone with temperatur...

Страница 16: ...s to hour 0 00 The symbol to indicate the regulation mode which has been set The time schedule is set starting from hour 0 00 towards 24 00 with steps of 30 minutes 3 By pressing the knob or the key the selection of the day of the week is moved WITHOUT modifying the previously set time program Valid only if the programmable thermostat has been configured in weekly programming 4 The time cursor is ...

Страница 17: ...he programmable thermostat has been set on Daily programming mode 8 If the programmable thermostat has been set on Weekly programming mode and it is required to set the time schedule by copying the time schedule set for the selected day 8a If the programmable thermostat has been set on Weekly programming mode and it is required to set the time schedule manually 8 When the setting for the current d...

Страница 18: ...button or wait 10 seconds without pushing any button In order to cancel the modifications done thus restoring the last time program set up and to exit the Hourly Schedule mode push the button 10 WARNING If it is needed to restore the default time schedule it is necessary to access the user parameter PAR 9 0 dFLt set default data in this case all the user parameters will be restored to factory valu...

Страница 19: ...d the Manual Set Point temperature 1 By pressing only once the button Manual 24 hours mode is activated 2 The display shows the symbol 24h manual 24h freetime evo remains on manual until 23 59 of the current day after which it returns to Automatic mode Note If Manual 24h mode is active and the Vacation mode is activated when the Vacation setting expires and if it is past the 23 59 the programmable...

Страница 20: ...shing the knob a countdown time When the countdown expires freetime evo is reset to the previously set operation mode 1 2 NOTE Turn the knob to set the Pause h hours or the Vacation d days From 1 to 95 hours the display shows the symbol to indicate the Pause mode From 4 to 99 days the display shows the symbol to indicate the Vacation mode The symbols blink indicating that the countdown is still to...

Страница 21: ...ob or the button or wait 10 seconds The symbols or are still lit and freetime evo starts the countdown 4 To exit the Pause or Vacation mode push at any time the button or 5 When the countdown is over freetime evo exits from the Pause or Vacation mode and resumes the previous operation mode ...

Страница 22: ...ed for more than 10 seconds 2 The display shows the first user parameter 3 Turning the knob scrolls through the 16 available user parameters H_C PAr 1 0 AFr PAr 2 0 Entc PAr 3 0 LinF PAr 3 1 LSUP PAr 3 2 OFS1 PAr 4 0 OFS2 PAr 5 0 HYSt PAr 6 0 tPI PAr 7 0 bP PAr 7 1 tInt PAr 7 2 PCYC PAr 7 3 PMIn PAr 7 4 tMIn PAr 8 0 EOrM PAr 9 0 dFLt PAr 10 0 Name of the parameter The icon shows that the user para...

Страница 23: ...of the selected parameter To continue the configuration of the other parameters repeat from point 3 7 To exit the configuration of the user parameters push the button or wait 30 seconds without pushing any button knob WARNING After 30 seconds of inactivity on the keys and or on the knob the programmable thermostat exits from user parameters setting mode and the display goes back to the normal oper...

Страница 24: ...he floor temperature must stay when regulating the room temperature In heating mode it will be possible to set a lower limit under which the floor temperature must not fall in order not to feel a cold floor while it will be possible to set a upper limit beyond which the floor temperature must not rise in order to guarantee the maximum wellness The programmable thermostat alerts when it is regulati...

Страница 25: ...g or cooling need of the room it will not be switched Off until the minimum On time is expired This parameter can be set in the range no 5 90 minutes with 5 minutes steps The device is factory set with the parameter to 0 i e function disabled EOrM PAr 9 0 EXTENDS OUTPUT DRIVING MODE TO THE OTHER CHANNELS OF THE RECEIVER This parameter has a meaning only if the programmable thermostat is coupled to...

Страница 26: ...eplace it with a new one The remote sensor temperature is not shown on the display The regulation of the room temperature is done using the internal sensor reading the user parameter Entc PAr 3 0 is set to no but you want to display the floor temperature set Entc PAr 3 0 to the value FLOS The display shows Err The remote sensor is used as a floor sensor the user parameter Entc PAr 3 0 is set to FL...

Страница 27: ......

Страница 28: ...SEITRON S p A a socio unico Via del Commercio 9 11 36065 Mussolente VI ITALY 39 0424 567 842 info seitron it www seitron com ...

Отзывы: