Seip Solar FR I Скачать руководство пользователя страница 4

4

CONNECTING THE BATTERY

To prevent the battery from discharging while in stock the Solar FRI is delivered with
one disconnected battery cable. To use the operator this cable must first be plugged
onto the open battery connector (please refer to the sketches aside) - or else the
operator will not work.

ATTENTION! The batteries are delivered fully charged - the capacity will allow up to 80
openings/closings. All the necessary adjustments during the installation can therefore
be made easily (generally 5 to 20 openings/closings). Nevertheless it is recommended
to avoid any unnecessary operation. If, however, the low-voltage indicator becomes
active (e.g. the battery-capacity is about to fall below the necessary minimum voltage)
then the operator automatically switches off until the batteries have been completely
recharged (by the solar panel)!

5

 ATTACHING AND DETACHING THE MOTOR HEAD

The sketches on the left show the attachment-procedure.

For the easier mounting of the C-rail (please refer to page 3) and to exchange the
batteries we recommend you detach the motor head from the C-rail.

The motor head is held in position by two fixing brackets. The brackets are secured by
one fixing-screw each. Loosening the fixing-screws enables the brackets to be turned -
procede as follows (the operator is lying in front of you, the housing is facing towards
you):

1. Slightly lift the fixing-brackets (away from the base-plate) - turn them to release the
C-rail.

2. Turn the motor-head counter-clockwise as far as possible

3. Pull the motor-head upwards to disconnect it from the C-rail.

To attach the motor-head to the C-rail please follow the procedure as shown in the
sketches on the left. Tighten the screws in the fixing-brackets to stop the brackets
turning by accident.

ATTENTION! The fixing-brackets are connected to electronic security-switches. If the
motor-head is not attached and fixed correctly to the C-rail the electric circuit is broken
- the operator will not work!
If, however, the motor-head starts turning after several operations because of
incorrect fixing then the electric circuit will be broken as well and the operator will not
work until the problem has been fixed.

Содержание Solar FR I

Страница 1: ...lly We disclaim all liability under the terms of the warranty for any damage caused by improper installation Approved according to the European Directives 89336 EEC and 73 23 EEC Installation Instructions for Automatic Garage Door Operators Solar FR I GB ...

Страница 2: ... C rail coupling pieces Your operator now is assembled for installation The chain has been pretensioned in the factory do not change the chain tension ATTENTION The limit switches of your operator have been put to a factory position Do not change this limit switch adjustment until the operator is fitted to the ceiling and the garage door Otherwise the carriage could crash into the motor head unit ...

Страница 3: ...Attach the C rail to the front fixing angle 4 Put a piece of cardboard under the motor head unit to avoid damage 4 To fix the motor head to the ceiling we recommend you use a ladder 5 When the operator is laying on the ladder you can open the garage door Adjust the C rail according to the mark you made in the middle of the garage door Fix the operator to the ceiling when you have made sure the C r...

Страница 4: ...e refer to page 3 and to exchange the batteries we recommend you detach the motor head from the C rail The motor head is held in position by two fixing brackets The brackets are secured by one fixing screw each Loosening the fixing screws enables the brackets to be turned procede as follows the operator is lying in front of you the housing is facing towards you 1 Slightly lift the fixing brackets ...

Страница 5: ...age door with the operator before you have tested the emergency release EMERGENCY RELEASE 7 LIMIT SWITCH SETTING 6 Your garage door opener automatically stops when one of the red limit switch actuators trips a limit switch in either CLOSING or OPENING direction Adjust the limit switches by hand OPENING direction Please set the limit switch actuator for the OPENING direction so that the door comes ...

Страница 6: ...acts again to signals from the hand transmitter or push button rubber bumpers Fix the solar panel to the bracket using the rubber bumpers as shown in the sketches on the left The cable connector must be positioned upwards Two screws help keep the correct distance from the ground Screws holding the panel in the correct distance from the ground To make the solar panel work efficiently it should be a...

Страница 7: ...r will start working Photo Cell Connector SI 2 If no photo cell is connected the bridge between the connectors must remain without the bridge the operator does not work When connecting a photo cell the bridge must be removed and the two impulse wires coming from the photo cell must be connected 24V DC power supply for external components Connectors SI 1 This connector supplies voltage as long as t...

Страница 8: ...er board for approx 10 sec You can release the button when the LED light goes on the memory then is cleared Coding the hand transmitter only applies to 12 bit remote controls If your operator has been delivered with a 12 bit remote control you must set up a code on your hand transmitter first Open your transmitter as shown on drawing C and set the switches to any code you like avoid putting all th...

Страница 9: ...ion with an angle of 60 held by the supplied metal bracket a daily sunlight of 600 Wh m2 is required to recharge the battery Information the average sunlight in December in Brimingham is approx 800 Wh m2 33 higher than required Batteries The expected life time of the batteries is approx 7 years Low Voltage Protection Should the battery capacity show a critically low voltage then an automatic low v...

Страница 10: ...AL FOR THE SAFETY OF PERSONS TO FOLLOW ALL INSTRUCTIONS Keep these Instructions Do not allow children to play with door controls Keep remote controls away from children Watch the moving door and keep people away until the door is completely closed Use caution when operating the manual release with the door open since it may fall rapidly due to weak or broken springs Details on how to use the manua...

Страница 11: ...triebe Short Range Device Funkgerät geringer Reichweite SRD complies with the essential requirements of 3 and the other relevant provisions of the FTEG Article 3 of the R TTE Directive when used for its intended purpose bei bestimmungsgemäßer Verwendung den grundlegenden Anforderungen des 3 und den übrigen einschlägigen Bestimmungen des FTEG Artikel 3 der R TTE entspricht 3 1 1 Article 3 1 a does ...

Страница 12: ...12 ...