MO910-V2
Prä ge.
Gn
d
8k2
Uext
24Vac
Gn
d
BT
Ue
xt
HF-MODUL/RECEIVER CARD
Ant
KRAFT/
PRESSURE
LERN/LEARN
TEST/RUN
24 V
16
LED-Lamps
Printed Circuit Board: Adjustments and Connections
LED
Function
ON
OFF
LED “TEST“
(green)
Turns on when:
1.) a device connected to A+B (push-button, key-switch) gives an
impulse
2.) the P.C.B.’s TEST-button is pressed
3.) a signal from a registered hand-transmitter is received
4.) the operator is in programming-mode
This LED also is being used for the programming of special
functions (pre-warning, time internal light)
Incoming impulse
No incoming im-
pulse
LED “Diag“
(red)
Turns on when:
1.) a safety-device recognizes an obstacle
2.) a short-cut is detected in the wiring of a security device
3.) a safety-device is not working properly
This LED also is being used for the programming of special
functions (pre-warning, time internal light)
Incoming impulse
from a programmed
hand-transmitter
No incoming im-
pulse from a hand-
transmitter
LED “Vp“
(yellow)
“ON“ when mains power supply is o.k.
Mains power supply
o.k.
No mains power
Содержание RP60A