seima.com.au
Island installation
1
See diagram below — there is a ledge between the wall and the side of the bath.
The minimum setout from the wall is 75mm. Refer to the local authority for local setout requirements.
2
Ensure that the area under the bath is
ventilated
in accordance with local requirements.
page 2 of 2
compressed cement
fibre sheet backing
tiling
sealant
fill
water stop
suitable moisture barrier
standard 40mm
waste outlet
unfinished
floor
run-off tube
tiles
sealant
grade sub-floor
1:60 minimum (or
local requirement)
wall
Please note
−
All measurements are in millimetres.
−
Dimensions are nominal and subject to normal ceramic manufacturing variations of ±5mm.
−
Fixing: Use acetic cured silicone sealant. Do not use epoxy type adhesives.
−
Specifications may vary without notice as part of our continuous improvement practices.
−
Clean with a damp cloth. Do not use abrasive cleaners, liquids or pastes.