5

CAL. 7T85

n

  TIME/CALENDAR

•  Hour, minute and small second hands
•  Date displayed in numerals 

n

  STOPWATCH 

• 

100-minute stopwatch in 1/5-second increments, consecutively measurable 

up to 

00 minutes (5 hours)

   

The second and minute STOPWATCH hands continue counting after the  

  10-minute hand reaches 100 minutes. So you can even measure accurate  

  time up to 109 minutes 59.8 seconds.  After that, the minute and 10-minute  

  STOPWATCH hands instantaneously return to the 0 or 10 minute position  

  respectively and continue counting again up to 00 minutes.

•   STOPWATCH hands
    - 1/5-second, 1-minute, and 10-minute hands

    - Minute counting is displayed by two types of STOPWATCH minute hands,  

    which move in reciprocating motion respectively.

•  Split time measurement on demand 
•  Demonstration Functon
    Demonstration of the stopwatch hand movement is available.

FEATURES

DISPLAY & BUTTONS

55

50

45

40

35

Hour hand

Small second hand

STOPWATCH 10-minute hand

Minute hand

a:  Normal position 

b:  First click 

    date setting

c:  Second click 

    time setting, 

    hand position adjustment

a  b    c

STOPWATCH 1-minute hand

STOPWATCH

 

1/5-second hand

CROWN

A

B

*  Some models may have a screw lock type crown. If your watch has a screw lock 

type crown, refer to  “ SCREW LOCK TYPE CROWN.”

*  The  “ 0” position of each stopwatch hand may differ depending on the model.   

In particular, in some models, the retrograde display in the 12 o’clock / 6 o’clock 

position may be oppositely oriented from the illustration above. In such cases, 

however, the method of operating the stopwatch according to this manual can be 

applied.  

Содержание SPC163P1

Страница 1: ...Cal 7T85 INSTRUCTIONS P 3 BEDIENUNGSANLEITUNG S 27 INSTRUCTIONS P 51 ISTRUZIONI P 75 INSTRUCCIONES P 99 INSTRUÇÕES P 123 147 ...

Страница 2: ...85 Pour obtenir d excellentes performances de cet article SEIKO veuillez lire attentivement cette brochure que vous conserverez pour toute référence ultérieure Grazie di aver acquistato questo orologio SEIKO Analogico al Quarzo Cal 7T85 Per ottenere i migliori possibili risultati da questo orologio leggere attentamente le istruzioni di questo manuale prima di utilizzare l orologio stesso Conservar...

Страница 3: ...hands which move in reciprocating motion respectively Split time measurement on demand Demonstration Functon Demonstration of the stopwatch hand movement is available FEATURES DISPLAY BUTTONS 55 50 45 40 35 Hour hand Small second hand STOPWATCH 10 minute hand Minute hand a Normal position b First click date setting c Second click time setting hand position adjustment a b c STOPWATCH 1 minute hand ...

Страница 4: ... may damage the screw hole in the case 55 50 45 40 35 How to unlock the screw lock type crown Turn the crown counterclockwise The crown is unlocked and can be operated How to lock the screw lock type crown Once you have finished operating the crown turn it clockwise while gently pressing it in toward the watch body until it stops l This watch is designed so that the following adjustments are made ...

Страница 5: ... of the desired time and then turn it back to the exact minute 2 STOPWATCH HAND POSITION ADJUSTMENT t Press for 2 seconds or longer STOPWATCH 1 minute hand turns a full circle Press repeatedly to set STOPWATCH 1 minute hand to the 0 position A Press for 2 seconds or longer B Press repeatedly to set STOPWATCH 1 5 second hand to the 0 position STOPWATCH 1 5 second hand STOPWATCH 1 5 second hand turn...

Страница 6: ...date appears t Push back in to normal position Date 1 Date setting should always be carried out after the time is correctly set 2 Manual date adjustment is required on the first day after a month that has less than 31 days February April June September and November 3 Do not set the date during any time between 9 00 P M and 1 00 A M Date setting during this time period may cause failure of date cha...

Страница 7: ... 300 minutes 5 hours of counting is illustrated below Before starting to use the stopwatch again make sure to reset the stopwatch by pressing Button B STOPWATCH l The measured time can be read up to 109 minutes 59 8 seconds in 1 5 second increments l When the measurement reaches 300 minutes 5 hours the stopwatch automatically stops counting l Split time measurement is possible How to read the stop...

Страница 8: ...TOPWATCH hands are reset to the 0 position If the STOPWATCH hands do not return to the 0 position when the stopwatch is reset to 0 follow the procedure in SETTING THE TIME AND ADJUSTING THE STOPWATCH HAND POSI TION STANDARD MEASUREMENT ACCUMULATED ELAPSED TIME MEASUREMENT SPLIT TIME MEASUREMENT MEASUREMENT OF TWO COMPETITORS STOP RESET START START START START STOP RESTART STOP RESET SPLIT SPLIT RE...

Страница 9: ...f the three STOPWATCH hands demonstrates high speed movements and when the demonstration is finished they return to the original position TACHYMETER for models with tachymeter scale l Tachymeter scale can be used only when the time required is less than 60 seconds To measure the hourly average speed of a vehicle U s e t h e s t o p w a t c h t o determine how many seconds it takes to go 1 km or 1 ...

Страница 10: ...its both light and sound For example it can indicate the distance to the place where lightning struck by measuring the time elapsed after you see a flash of lightning until you hear the sound l A flash of lightning reaches you almost immediately while the sound travels to you at a speed of 0 33 km second The distance to the source of the light and sound can be calculated on the basis of this diffe...

Страница 11: ...nd the small second hand moves at two second intervals instead of normal one second intervals In that case have the battery replaced with a new one as soon as possible The watch remains accurate while the small second hand is moving at two second intervals The miniature battery which powers your watch should last approximately 3 years However because the battery is inserted at the factory to check...

Страница 12: ...ting the IC will initialize the watch Before starting to use the watch it will be necessary to set the time and adjust the STOPWATCH hands to the 0 position Refer to SETTING THE TIME AND ADJUSTING THE STOPWATCH HAND POSITION section of this manual Necessary procEdure after battery change After the battery is replaced with a new one or when an abnormal display appears follow the procedures below to...

Страница 13: ...rn the watch to a normal temperature so that it works accurately as usual and then reset the time The watch has been adjusted so that it works accurately when it is worn on your wrist under a normal temperature range between 5 ºC and 5 ºC Solutions Have the battery replaced with a new one immediately by the retailer from whom the watch was purchased Correct this condition by moving and keeping the...

Страница 14: ...minute and small second hands in 1 second increments Stopwatch Stopwatch 1 5 second hand in 1 5 second incre ments 60 seconds 360 degrees Stopwatch 1 minute hand in 1 minute incre ments 40 minutes 240 degrees Stopwatch 10 minute hand in 10 minute incre ments 100 minutes 240 degrees 6 Battery SEIKO SR927SW 1 piece 7 Battery life Approximately 3 years If the stopwatch is used less than 5 hours per d...