32
USB Interface
USB 2.0 Full-Speed.
The following table provides the standardized contact terminating assignments by number and
electrical value for Series “A” and Series “B” connectors.
Contact Number
Signal Name
Typical Wiring Assignment
1 VBUS
Red
2 D-
White
3 D+
Green
4 GND
Black
Shell
Shield Wire
Command Code Summary
Epson Emulation
Name
Code
(Symbol)
Code
(Hex.)
Code
(Dec.)
Print and Line Feed Execution
Carriage Return
CR
0D
h
13
d
Line Feed
LF
0A
h
10
d
n/180” Line Feed
ESC J
1B
h
4A
h
27
d
74
d
n/180” Reverse Line Feed
ESC j
1B
h
6A
h
27
d
106
d
Format Control
Set 1/8” Line Spacing
ESC 0
1B
h
30
h
27
d
48
d
Set 1/6” Line Spacing
ESC 2
1B
h
32
h
27
d
50
d
Set n/180” Line Spacing
ESC 3
1B
h
32
h
27
d
51
d
Set n/60” Line Spacing
ESC A
1B
h
41
h
27
d
65
d
Set n/360” Line Spacing
ESC +
1B
h
2B
h
27
d
43
d
Form Feed
FF
0C
h
12
d
Set Form Length in Lines
ESC C
1B
h
43
h
27
d
67
d
Set Form Length in Inches
ESC C NUL
1B
h
43
h
00
h
27
d
67
d
0
d
Set Form Length in Defined Unit
ESC ( C
1B
h
28
h
43
h
27
d
40
d
67
d
Select Skip-Over-Perforation
ESC N n
1B
h
4E
h
27
d
78
d
Cancel Skip-Over-Perforation
ESC O
1B
h
4F
h
27
d
79
d
Vertical Tab
VT
0B
h
11
d
Set Vertical Tab Positions
ESC B
1B
h
42
h
27
d
66
d
Select a VFU Channel
ESC /
1B
h
2F
h
27
d
47
d
Select VFU Positions
ESC b
1B
h
62
h
27
d
98
d
Set right Margin
ESC Q
1B
h
51
h
27
d
81
d
Содержание PRECISION FB 380
Страница 1: ...SEIKO Precision FB 380 Dot Matrix Flatbed Printer USER MANUAL ...
Страница 41: ......
Страница 42: ......
Страница 43: ......
Страница 44: ......
Страница 45: ......
Страница 46: ......
Страница 47: ......
Страница 48: ......
Страница 50: ...Company name SEIKO PRECISION Europe GmbH Address Hermann Buck Weg 9 D 22309 Hamburg Germany ...